Herunterladen Inhalt Inhalt Diese Seite drucken

Threshold Values For The Temperature Warning; Sensor Operating Hours; Boot Cycle Counter - Balluff BMF 415KW-HA W-5-Serie Betriebsanleitung

Vorschau ausblenden Andere Handbücher für BMF 415KW-HA W-5-Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BMF 415KW-HA _ _ _ -W-5- _ _ -...
Magnetic Field Sensors
6
IO-Link interface (continued)
6.5.6

Threshold values for the temperature warning

The BMF 415KW-HAKKI allows you to define temperature
warning thresholds. The threshold can be set in the range
from 0...+80 °C. If these threshold values are exceeded or
too low, the BMF outputs a warning (see section 6.6.2
Event list on page 18). If the internal temperature of the
BML exceeds 90 °C, an overtemperature error is output.
Index
Subindex Name
1
Device
Temperature
0x0053 (83)
2
Tab. 6-11: Parameter threshold for temperature warning
6.5.7

Sensor operating hours

The operating hours are detected in the
BMF 415KW-HAKKI-... and permanently stored at hourly
intervals. Using system command Reset Maintenance, the
sensor operating hours for maintenance is reset to zero.
Index
Subindex Name
1
Operating
Hours
2
0x0057 (87)
3
Tab. 6-12: Parameter sensor operating hours
6.5.8

Boot cycle counter

The BMF 415KW-HAKKI-... increments the permanently
stored boot cycle counter at each reboot. Both system
command Device Reset as well as a hardware restart lead
to an increase of the counter. Using system command
Reset Maintenance, the boot cylinder counter for
maintenance is reset to zero.
Index
Subindex Name
Boot Cycle
Counter
0
0x0058 (88)
Tab. 6-13: Parameter boot cycle counter
16
english
Threshold for minimum
temperature exceeded
Threshold for maximum
temperature exceeded
Operating hours over the
entire service life
Operating hours since last
maintenance
Operating hours since last
power-on
Boot cycle counter
Size
Access
Values
16-bit value in units of °C
2 bytes
Read/Write
0x0000...0x0050 (0...80)
16-bit value in units of °C
2 bytes
Read/Write
0x0000...0x0050 (0...80)
Size
Access
Values
4 bytes
Read Only
32-bit value in units of h
4 bytes
Read Only
32-bit value in units of h
4 bytes
Read Only
32-bit value in units of h
Size
Access
Values
4 bytes
Read Only
32-bit value