BMF 415KW-HA _ _ _ -W-5- _ _ -...
Magnetic Field Sensors
6
IO-Link interface (continued)
6.3
Identification data
Index
Subindex
0x0010 (16)
0
0x0011 (17)
0
0x0012 (18)
0
0x0013 (19)
0
0x0014 (20)
0
0x0015 (21)
0
0x0016 (22)
0
0x0017 (23)
0
0x0018 (24)
0
0x0019 (25)
0
0x001A (26)
0
The size of the respective parameter may deviate from the maximum indicated size.
1)
Tab. 6-3:
Identification data
Application Specific Tag, Function Tag and
Location Tag
The tags Application Specific Tag, Function Tag and
Location Tag, make it possible to assign the IO-Link device
any max. 32-byte string. This can only be used for
application-specific identification and applied in the
parameter manager. The entire object is accessed via
subindex 0.
6.4

System commands

Different commands have been implemented in the
BMF 415KW-HAKKI-... which can be reached via the
System Command parameter. If a system command is
transferred to the BML, the command triggers the desired
action if permitted in the current application state.
Index
Subindex Command Name
0x0002
0
0x01 (1)
(2)
0x02 (2)
0x03 (3)
0x04 (4)
0x05 (5)
0x80 (128)
0x82 (130)
0xA5 (165)
Tab. 6-4:
System commands
www.balluff.com
Parameter
Vendor Name
Max. 32 bytes
Vendor Text
Max. 32 bytes
Product Name
Max. 64 bytes
Product ID
Max. 8 bytes
Product Text
Max. 64 bytes
Serial Number
Max. 16 bytes
Hardware Revision
Max. 4 bytes
Firmware Revision
Max. 32 bytes
Application Specific Tag
Max. 32 bytes
Function Tag
Max. 32 bytes
Location Tag
Max. 32 bytes
ParamUploadStart
ParamUploadEnd
ParamDownloadStart
ParamDownloadEnd
ParamDownloadStore
Device Reset
Restore Factory Settings
Reset Maintenance
Size
Access
1)
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read/Write
Read/Write
Read/Write
Description
Starts parameter upload.
Ends parameter upload.
Starts parameter download.
Ends parameter download.
Completes the configuration and starts the data storage.
Re-initializes all device components.
Resets all configurations to the factory setting.
Resets all operating parameters.
Data storage
X
X
X
english