Werbung

Verfügbare Sprachen

Verfügbare Sprachen

RS485 Half-duplex transmission with the following features:
Parameter reading Select the enabled parameters via the key
Resetting of batch counter 1. Display count.
Setting of parameters 1. Display parameter.
- symmetrical
- 2 lines
- multi-point connection – emitter and receiver (max. 32 units)
- maximum distance of data transmission: 1500 m
➜ Assign contacts 14 (T,R-) and 15 (T,R+) accordingly.

4 Operating mode

The following chapter will inform you on the operation.
● The counter is automatically on the operator level after the supply
voltage has been turned on.
On the operator level it is possible:
- to read and, if necessary, clear the current count;
- to read and, if necessary, modify the presets P1 and P2;
- to read and, if necessary, modify the totalizer;
- to read and, if necessary clear the batch counter.
It is possible to disable all operator parameters on the programming
level (Lines 11-16).

4.1 Key functions

The key
allows to switch to the next operation parameter.
For quick sweep, keep this key depressed.
2. Press
key.
2. Press
or
key and select required decade;
chosen decade position blinks.
3. Press
or
key and enter required value.
To set further decades, repeat steps 2 and 3.
4. Confirm the parameter entered with
Should no confirmation be given within 15 s, the previous setting
will remain valid.