Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30

English

!
in compliance with the instructions provided.
- If the hood is left on (lights and/or motor), after 10
hours in the absence of commands from the user, it
will automatically switch to OFF condition with all
services switched off.
- The Buzzer emits a "beep" each time that a
command is set from the keyboard or remote control
(optional)
- In the event of interruption of power during the hood,
if you restore the hood in the OFF state, then the
engine must be reactivate manually.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard
Wear gloves when carrying out installation and
!
maintenance operations.

AIR VENT

(for ducting versions)
! Prepare the hole and the air vent duct (150 mm dia-
meter).
! Use a duct of the minimum indispensible length.
! Use a duct with as few elbows as possible (maximum
elbow angle: 90°).
! Avoid drastic changes in the duct cross-section.
! Use a duct with an as smooth as possible inside.
!
! Do not connect the hood to smoke exhaust ducts
stoves, etc).
! For the air vents comply with the provisions laid down
by the competent authorities.
In addition, the air must not be evacuated through a
purpose.
! Fit air intakes in the room to prevent the hood from
creating a negative pressure in the room (which must
not exceed 0.04 mbar); if the hood is used at the
same time as non-electrical equipment (gas-, oil- and
sucked in by the heat source.
Ducting version
through an exhaust duct (diameter 150 mm).
CONTROLS
P1
P3
P5
P2
P1: 5' TIMER
P2: Filter alarm reset
P3: Motor off / speed decrease – .
- holding down the button, the motor turns off sto-
ring the current speed
P4: Motor on / speed increase
P5: Lights on/off
L1 Signalling crown:
-
Hood in standby: 30" after
the last key has been pressed the crown turns off
-
Motor on:
-
5' TIMER function :
-
Filter alarm active:
The 4th speed (intensive) is automatically lowered to 3rd
speed after 5 minutes of operation to optimise energy
consumption.
P4
L1

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis