Herunterladen Inhalt Inhalt Diese Seite drucken

English; Air Vent - Best Gloss Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Gloss:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14

english

! The appliance must be installed by a qualified person
eN
in compliance with the instructions provided.
Wear gloves when carrying out installation and
maintenance operations.

aIr VeNT

(for ducting versions)
! Prepare the hole and the air vent duct (150 mm dia-
meter).
! Use a duct of the minimum indispensible length.
! Use a duct with as few elbows as possible (maximum
elbow angle: 90°).
! Avoid drastic changes in the duct cross-section.
! Use a duct with an as smooth as possible inside.
! The duct must be made of certified material.
! Do not connect the hood to smoke exhaust ducts
for the products of combustion (boilers, fireplaces,
stoves, etc).
! For the air vents comply with the provisions laid down
by the competent authorities.
In addition, the air must not be evacuated through a
hole in the wall unless specifically intended for this
purpose.
! Fit air intakes in the room to prevent the hood from
creating a negative pressure in the room (which must
not exceed 0.04 mbar); if the hood is used at the
same time as non-electrical equipment (gas-, oil- and
charcoal-fired stoves, etc.) the exhaust gas may be
sucked in by the heat source.
FIlTerING or dUcTING VerSIoN ?
The hood may be in filtering or in ducting version. Deci-
de from the outset which type is to be installed.
For better efficiency, we recommend installing the hood
in the ducting version (if possible).
ducting version
The hood purifies the air and evacuates it to the outside
through an exhaust duct (diameter 150 mm).
Filtering version
The hood purifies the air and recycles the clean air
back into the room. For this version, the following are
required: 1 air baffle, 1 reducer, 1 charcoal filter.
The upper flue air evacuation slots must be positioned
at the top.
12
coNTrolS
a) Turns the LIGHTS off
B) Turns the LIGHTS on.
c) Decreases speed down
to minimum speed. If
pressed for 2" the motor is
turned off.
d) Activates the motor
(calling the last speed
used) and increases the
speed until reaching ma-
ximum.
e) FILTER ALARM/TIMER
RESET: when pressing
the key during display of
the filter alarm (motor off)
it resets the hour counter.
When pressing the key
when the motor is running,
the TIMER is activated
and the hood will automa-
tically be switched off after
5 minutes.
l1) The 4 green LEDs in-
dicate the running speed.
l2) When the LED is
red (motor off) it indica-
tes the FILTER ALARM.
When the LED is green
(flashing) it indicates that the TIMER has been activated
with the key E.
FILTER ALARM:
After 30h of operation, the LED L2 turns RED. It indica-
tes that the grease filters need to be cleaned.
After 120h of operation, the LED L2 turns RED and
flashes; It indicates that the grease filters need to be
cleaned and the charcoal filters replaced.
After cleaning the grease filters (and/or replacing the
charcoal filters), restart the hour counter (RESET) by
pressing the key E during display of the filter alarm.
L2
E
R
L1
D
OFF/+
C
OFF/-
B
ON
A
OFF

Werbung

Inhaltsverzeichnis
loading