Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
2. Lower the control panel at the front by carefully pulling it downwards. You can now
access the light module and terminals. Replace the lamp (commercially available
LED lamp, max. 1.5 W).
Ø
Max. Power
(Watt)
70 mm
1,5 W

TROUBLESHOOTING

Problem
Light on, but motor does
not work
Both light and motor do
not work
Oil leaks.
Voltage
Picture
(Volt)
DC 12 V
Possible Cause
The blades are blocked.
The capacitor is damaged.
The motor is damaged.
The internal wiring of
the motor is cut off /
disconnected. An
unpleasant smell may be
produced.
Apart from the above mentioned, check the following:
The light is damaged.
The power cord is loose.
The air outlet and the air
ventilation entrance are
not tightly sealed.
Lamp
ILCOS D
Cap
code
- -
DSR-
1.5-S-70
Possible Solution
Check the blades.
Replace the capacitor.
Replace the motor.
Replace the motor.
Replace the light module.
Connect the wires
according to the electric
diagram.
Take down the outlet and
seal it with glue.
EN
33

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis