3.6 – settIng the mInImum Central heatIng temperature
- press either of the
- press these keys until the display shows P5, referring to the temperature to be set;
-
press the
keys to set the temperature required.
This operating mode is enabled when minimum temperature central heating mode
heating program does not require heat.
note –
With the outdoor sensor probe connected, parameter p5 can be used to set the minimum room tempe-
rature in the premises to be heated.
parameter
parameter description
n.
p1
Time of day setting
p5
Minimum central heating temperature setting (°C)
p11
Start of first daily period of automatic central heating
p12
End of first daily period of automatic central heating
p13
Start of second daily period of automatic central heating
p14
End of second daily period of automatic central heating
p15
Start of third daily period of automatic heating
p16
End of third daily period of automatic central heating
p31
Start of first daily period of domestic hot water production
p32
End of first daily period of domestic hot water production
p33
Start of second daily period of domestic hot water production
p34
End of second daily period of domestic hot water production
p35
Start of third daily period of domestic hot water production
p36
Fine End of third daily period of domestic hot water production
Reset of daily central heating and domestic hot water production programs (factory
p45
settings).
Press the - + keys together for about 3 seconds; the number 1 appears on the
display. Confirm by pressing either of the
note –
Parameters from
described in chapter 17 for the attention of the installer (parameter H91).
3.8 - fault warnIngs anD resettIng the boIler
If a fault occurs, a flashing warning code appears on the display.
The fault warnings appear on the main display (figure 1 a) together with the
To reset, press the reset
Figure 4
InstructIons pertaInInG to the user
keys to access the programming function;
3.7 – table of user-settable parameters
p31
p36
to
can be displayed only if the domestic hot water program has been enabled as
button for at least two seconds
is activated or when the daily central
symbol (Figure 4).
.
39
Factory
range
setting
———-
0...23:59
25
25..80
6:00
00:00...24:00
22:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
24:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0
0...1
926.423.1 - GB