Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Problems, Possible Causes And Solutions - EBARA 3TP Serie Installations- Und Wartungshandbuch

High speed unterwasserpumpen
Vorschau ausblenden Andere Handbücher für 3TP Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
8.

MAINTENANCE

The 3TP pump does not normally need any maintenance.
In order to prevent possible damage to the pump, it is advisable to make periodic checks of the
power absorption and the pump head. It is not necessary to remove the pump from the well to
carry out checks.
The supply cable must only be removed by qualified technicians.
All repairs must be carried out by qualified technicians.
ATTENTION
9.
PROBLEMS POSSIBLE CAUSES AND SOLUTIONSI
Before beginning any work on the pump, check that the power supply has been
removed.
The megger test is not permitted on the 3TP because the electronic system could
ATTENTION
be damaged.
9.1. The pump does not start or there is a low delivery of water.
The non-return valve is closed
The wrong pump has been chosen; too little water in
the well
Pipe is broken or blocked
The pump filter is blocked
Pump blocked or valve not working
Water leakage in the installation
Defective pump
9.2. The pump head is not sufficient
Too little water in the well for the type of pump
Wrong pressure
Leakage from the installation
Pump worn
The impellers are blocked
9.3. The pump does not rotate
The protection fuses are blown
The differential trip switch has tripped
There is no power
The motor protection has caused the differential trip
switch to trip
The pump or the supply cable are defective
Excessive or insufficient voltage in the power supply
9.4.
St
art-ups are too frequent
The calibration of the pressure switch is not correct
The non-return valve is leaking or stays partially open
The voltage on the power supply is not stable
.
.
.
Check the valve
Remove the pump and choose a more suitable pump
for the characteristics of the well
Repair the pipe
Clean the pump filter
Remove the pump and repair it
Check the leakage
Remove the pump and check it. Substitute it if
necessary
Remove the pump and install one that is more
suitable for the type of well. (Be careful not to install
the pump at the bottom of the well)
Check the setting of the pressure switch
Check the leakage from the installation
Check the pump and replace the worn out parts
Remove the pump and check
Check the fuses
Check it
Check the supply
Check that the pump is not blocked
Repair or substitute the cable
Check
Increase the pressure differential. The stop pressure
must not be superior to operating pressure and the
start pressure must be sufficiently high to ensure
sufficient water supply
Check the valve
Check it
16 - ENG
.