Overview of the terminal assignment

This overview indicates which system parts can be connected for all
terminals in the module. Depending on the system, one of the
components can be connected to the terminal (e.g. "VR2" or "PR2" to the
terminal "VR2"). Depending on what the module is used for,
simultaneous connection of a number of components may be required,
or may need to be excluded.
120/230VAC 120/230VAC
4
43 44
N L
N
N
N L
M
M
M
M
VR2*
VR1
PR1
230 V AC
PR2*
Legend for fig. above and figs. 22 for 30 at the end this document
(terminal designation  Tab. 4 and 5):
grau
Components with a grey background can be connected
as an option
*
Components of the system are possible alternatives
230 V AC Mains voltage connection
AHS
Alternative heat source with signal input; extra-low voltage
or mains voltage side; On/Off or 0-10 V signal for modulation
(Alternative Heat Source) (Alternative Heat Source)
AHSP
Alternative heat source without signal input
(Alternative Heat Source Passive)
B
Buffer cylinder (Buffer)
BC
Basic controller, e.g. BC10 (Basic Controller)
CC
Combi cylinder (Combi Cylinder)
CHC
Conventional heat source: condensing storage combi heating
centre (Combi Heating Centre)
CON
Control unit with EMS plus BUS system; signal input/output
for systems with conventional and alternative heat sources
and coding switch setting one (Controller)
CONM
Control unit with EMS plus BUS system; signal input/output
for systems with stand-alone alternative heat sources and
coding switch setting 10 (Controller Master)
DHWC
DHW cylinder (Domestic Hot Water Cylinder)
HS
Conventional heat source (Heat Source)
Connection HS to OEV only with control units with EMS1.0;
the connection is not required with control unit series
Logamatic MC110 from V1.44
FS
Freshwater station (Freshwater Station)
1) Terminal assignment on extra-low voltage side: 1, 2 – On/Off (max. 24 V);
3 – earth; 4 – 0-10 V signal
AM200 – 6720884574 (2018/04)
AM200
120/230 V AC
VR2
VR1
PR1
N 14
N
43 44
N 14
120/230 V AC
VB1
OA3
N L
N
L
N 43
44 15
16
4
43 44
N
M
230 V AC
VB1
AHS/
AWE
4 5 6
3
7
2
8
1
9
10
10
0
24V
TR1 TB1
TB2 TB3
TB4
1 2 1 2
1 2 1
2 1
2
24V
OA1
OA2
TR2
T1
OEV
on/off
0-10V
Adr.9-10
1 2 1 2
1 2 1
2 3
4
N
T1
TR2
HS
AHS/
CONM
AWE
(autark)
MC
Master controller, e.g. MC110 (Master Controller)
PR1
120/230 V AC: pump of alternative heat source
(Pump Return); ≤ 24 V: control signal
alternative heat sources (0-10 V/PWM) for output control
PR2
Connection of pump for heating circuit 1 with stand-alone
alternative heat sources
1)
Solar module (Solar Module)
SM/MS
T1
Outside temperature sensor, only required with coding
switch setting 10 (Temperature sensor),
TA1
Alternative heat source flow temperature sensor
(Temperature Alternative)
TB1
Buffer cylinder temperature sensor at top
(Temperature Buffer)
TB2
Buffer cylinder temperature sensor at centre
TB3
Buffer cylinder bottom temperature sensor
TB4
System flow temperature sensor
TF1
Alternative heat source flue gas temperature sensor
(Temperature Flue gas)
TR1
Alternative heat source return temperature sensor
(Temperature Return)
TR2
Heating system return temperature sensor
VB1
Mixer connection
VR1
Mixer connection
(Valve Return)
VR2
Connection of diverter valve to bypass conventional heat
source
2) Terminal assignment: 1 - earth; 2 - pulse width modulation/0-10 V output;
3 - pulse width modulation input
3) Note with diverter valve: terminal 43 acts in direction of buffer cylinder
Installation
1 2 3
PWM
TA1
TF1
OR1
TF1
PR1
1 2
3
4
1
2 3
BUS
BUS
BUS
1 2
1
2
1 2
CON
CON
TR1
TB1
TB2
BC/MC
BC/MC
2)
3)
Buffer cylinder return (Valve Buffer)
3)
Alternative heat source return
3
0-10V
TB3
TB4
TA1
0010013960-002
with stand-alone
19