Herunterladen Inhalt Inhalt Diese Seite drucken

Start-Up Procedure; Limits Of Use - OLI MVE J Serie Handbuch

Elektrische aussenrüttler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

MVE
C
Ensure the electric motovibrator and the equipment to which it is connected are safe.
The operation must only be carried out by qualified staff.
Power off the motovibrator during the disassembly and reassembly of the protective parts (covers, exposed conductive parts and terminal
board cover).
Absorbed current check:
- Power on the motovibrator and use an amperometric clamp on all the phases to ensure the absorption does not exceed the value
reported on the rating plate. Otherwise, make sure the structure or elastic system on which the motovibrator is applied has been in
turn applied correctly.
- Never touch the motovibrator during operation.
- Never start the motovibrator without the protection covers of the exposed conductive parts and the terminal board cover.
- After a short period of operation, check again the tightening of the motovibrator fastening elements to the structure.
COMPLY WITH THE VALUES REPORTED ON THE RATING PLATE OF THE MOTOVIBRATOR.
The weighted equivalent continuous sound pressure level of the motovibrators NEVER exceeds 76 dB(A)*
*Measurement carried out under normal operating conditions according to ISO 6081/86, with a simulated load consisting of a spring-
mounted iron bench.
** Motovibrators equipped with bearings from NJ2320 to NJ2330 with a brass cage can be noisier.
However, the manufacturer of the machine inside which the motovibrator is incorporated is required to carry out final noise level
measurements on the system or finishing machinery. Likewise, the employer MUST carry out the noise level measurements in the work
environment where the system or machinery inside which the motovibrator is incorporated is installed. These measurements must be
taken before the system is started up. It is also mandatory to use adequate personal protection and training equipment, as per Legislative
Decree no. 81 of 9 April 2008.
ALONG WITH THE ABOVE, COMPLY WITH THE STANDARDS IN FORCE IN THE COUNTRY WHERE YOU
OPERATE.
The temperature of the environment where the machine operates is:
J
H
E
The user is responsible for complying with regulations related to workplaces with an explosion hazard due to the presence of combustible
powders
- IEC 60079-10-2
- NEC 500.5
- CEC C22.1
CM
US
Intertek

2.6 - START-UP PROCEDURE

2.7 - LIMITS OF USE

Certification
II2 D Ex tb IIIC Tx Db IP66
II2 D Ex tb IIIC Tx Db IP66
II2 D Ex tb IIIC Tx Db IP66
CM
Class II Div 2 Group F,G T4
C
US
Intertek
Ex tb IIIC Tx Db IP66
T.Amb -20/+40°C
Ex tb IIIC Tx Db IP66
T.Amb -20/+55°C
Ex tb IIIC Tx Db IP66
Ex tb IIIC Tx Db IP66
T.Amb -20/+40°C
2
M. 55
REV.01 | 01/2019

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mve h serieMve e serie

Inhaltsverzeichnis