Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Shut-Down - Silvercrest SKWH 2000 A1 Bedienungs- Und Sicherheitshinweise

Keramik wandheizlüfter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

13. Once you have set all 7 days of the week, the
week timer is active. Depending on the function,
the indicators
and
A
If values
and
are lit continuously, the selected
A
B
program is active or the device turns off automatically.
If values
and
blink, it means that the selected
A
B
program is not yet in use. Then the device switches off
after 30 seconds again. In the meantime, the fan runs
until the standby mode. Values
to blink until the program automatically intervenes
and turns the device on.
DEACTIVATION OF THE WEEKS TIMER
You can disable all the week timers, by pressing the
week timer button
again, after P6 is shown. Then
9
the reading in the display extinguishes. Alternatively,
you can use the week timer button
ately press the cancel button
also be disabled by once pressing the ON/OFF button,
while the value
blinks.
B
DETECTION OF OPEN WINDOWS
These are repeated measurement cycles. Each of them
will run 10 minutes. For each cycle, the following measure-
ments will be made: a start measurement, a first compari-
son measurement after 5 minutes and another comparison
measurement after 10 minutes. If one of the two compari-
son measurements is more than 8°C lower than the start
measurement, the device will detect it as an open window
and automatically switch off.
1. Turn on the device (see 'Starting')
2. Select one of the two heating levels (see 'Heating
Level Setting').
Please note: The window test can only be carried
out when a heating level is selected, not in the fan
setting mode.
16
GB/IE/NI/CY
light or blink.
B
and
continue
A
B
and then immedi-
9
. The weekly timer can
6
3. Press the window key
on the display starts to blink :
D
4. The first measuring cycle the window measurement
starts after 1 minute.
5. The first comparison measurement is carried out
after more 5 minutes. If the measured temperature
is more than 8°C below the start measurement, the
device turns off and the window check is comple-
ted. If this is not the case, the device will continue to
heat and the test will go on.
6. The second comparison measurement is made10
minutes after the start measurement. If the measured
temperature is more than 8°C below the start mea-
surement, the device turns off and the window check
is completed. If this is not the case, the second com-
parison measurement will be taken as a new start
measurement and the new measurement cycle will
start and run as described in steps 4 and 5.
7. As far as you do not finish the window test by
pressing the window button
and 5 until you see a temperature drop of 8°C
within a cycle.
As soon as the device detects an open window, it stops
to heat. An audible alarm will sound for 5 seconds and
the fan will run 30 seconds till the standby mode. The
temperature indicator
D
blinking on the display. While LED "OF" blinks, the swit-
ched-off device is at the "open-window" mode.
Please note: when the window test is completed, the
device must be started manual, if desired. To do so,
press the on/off button
1
turn the device off. The heater switches off. The blinking
temperature indicator
D
tor "OF" will be deleted.

SAFETY SHUT-DOWN

If the measured room temperature 51°C, the device swit-
ches off automatically. The fan runs 30 seconds before it
turns off. A countdown is shown on the display.
. The temperature display
3
, repeat steps 4
3
and the LED "OF" are shown
on the remote control unit to
on the display and the indica-

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis