Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting The Control Medium; Optical Position Indicator; Assembly / Disassembly Of Spare Parts; Valve Disassembly (Removing Actuator From Body) - Gemü 695 Original Einbau- Und Montageanleitung

Membranventil
Vorschau ausblenden Andere Handbücher für 695:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Control function
1 (NC)
2 (NO)
3 (DA)
+ = available / - = not available
(for connectors 2 / 4 see pictures above)
10.3
Connecting the
control medium
Important:
Connect the control medium lines
tension-free and without any bends
or knots!
Use appropriate connectors
according to the application.
Thread size of the control medium
connectors: G1/4
Control function
1
Normally closed (NC)
2
Normally open (NO)
3
Double acting (DA)
For connectors 2 / 4 see pictures above
Connector 2
Control function 1
Connector 4
Connector 2
Control function
2 + 3
Connectors
2
4
+
-
-
+
+
+
Connectors
2: Control medium (open)
4: Control medium (close)
2: Control medium (open)
4: Control medium (close)
10.4

Optical position indicator

Control function 1: standard
Control function 2 + 3: optional accessories
Valve open
11
Assembly / disassembly
of spare parts
19
18
11.1
Valve disassembly (removing
actuator from body)
1. Move actuator A to the open position.
2. Remove actuator A from valve body 1.
3. Move actuator A to the closed position.
Important:
After disassembly, clean all parts
of contamination (do not damage
parts). Check parts for potential
damage, replace if necessary (only
use genuine parts from GEMÜ).
29 / 40
Valve closed
A
2
1
695