Installation - Butt weld spigots:
1. Adhere to good welding practices!
2. Disassemble the actuator with the
diaphragm before welding the valve body
into the pipeline (see chapter 11.1).
3. Allow butt weld spigots to cool down.
4. Reassemble the valve body and the
actuator with diaphragm (see chapter
11.4).
Installation - Clamp connections:
When assembling clamp connections,
G
insert a gasket between the body clamp
and the adjacent piping clamp and join
them using the appropriate clamp fi tting.
The gasket and the clamp for clamp
connections are not included in the scope
of delivery.
Important:
Butt weld spigots /
Clamp connections:
Angle of rotation for welding into
pipeline to enable optimised
draining see brochure
"Angle of rotation" (on request
or www.gemu-group.com).
Installation - Threaded connections:
Screw the threaded connections into the
G
piping in accordance with valid standards.
Screw the diaphragm valve body into the
G
piping, use appropriate thread sealant.
The thread sealant is not included in the
scope of delivery.
Installation - Flange connection:
1. Pay attention to clean, undamaged
sealing surfaces on the mating fl anges.
2. Align fl anges carefully before installing
them.
3. Centre the seals accurately.
4. Connect the valve fl ange and the piping
fl ange using appropriate sealing material
and matching bolting. Sealing material
and bolts are not included in the scope
of delivery.
5. Use all fl ange holes.
695
6. Only use connector elements made of
approved materials!
7. Tighten the bolts diagonally!
Observe appropriate regulations for
connections!
After the installation:
Reactivate all safety and protective
G
devices.
10.2

Control functions

The following control functions are available:
Control function 1
Normally closed (NC):
Valve resting position: closed by
spring force. Activation of the actuator
(connector 2) opens the valve. When the
actuator is vented, the valve is closed by
spring force.
Control function 2
Normally open (NO):
Valve resting position: opened by
spring force. Activation of the actuator
(connector 4) closes the valve. When the
actuator is vented, the valve is opened by
spring force.
Control function 3
Double acting (DA):
Valve resting position: no defined normal
position. The valve is opened and closed
by activating the respective control
medium connectors (connector 2: open /
connector 4: close).
28 / 40