Herunterladen Inhalt Inhalt Diese Seite drucken

Carl Valentin Spectra 107/12 Kurzanleitung Und Hinweise Zur Produktsicherheit Seite 82

Drucksysteme
Vorschau ausblenden Andere Handbücher für Spectra 107/12:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Spectra
Stray Radiation and Immunity from Disturbance
Emitted interference according to EN 61000-6-4: 08-2002
Interference voltage to wires according to EN 55022: 09-2003
Interference field power according to EN 55022: 09-2003
Immunity to interference according to EN 61000-6-2: 03-2006
Stray radiation against discharge of static electricity according to EN 61000-4-2: 12-2001
Electromagnetic fields according to EN 61000-4-3: 11-2003
Fast transient burst according to EN 61000-4-4: 07-2005
Surge according to EN 61000-4-5: 12-2001
High-frequency voltage according to EN 61000-4-6: 12-2001
Voltage interruption and voltage drop according to EN 61000-4-11: 02-2005
NOTICE!
This is a machine of type A. This machine can cause interferences in residential areas; in this case it can be required
from operator to accomplish appropriate measures and be responsible for it.
Connecting Lines to External Machines
All connecting lines have to be guided in shielded lines. Shielding has to be connected on both sides to the corner shell.
It is not allowed to guide lines parallel to power lines. If a parallel guiding cannot be avoided a distance of at least 0.5 m has to
be observed.
Temperature of lines between: −15 ... +80 °C.
It is only allowed to connect devices which fulfil the request 'Safety Extra Low Voltage' (SELV). These are generally devices
which are checked corresponding to EN 60950/EN 62368-1.
Installation of Data Lines
The data cables must be completely protected and provide with metal or metallised connector housings. Shielded cables and
connectors are necessary, in order to avoid radiant emittance and receipt of electrical disturbances.
Allowable lines
Shielded line:
Sending and receiving lines have to be twisted in pairs.
Maximum line length:
Air Convection
To avoid inadmissible heating, free air convection has to be ensured.
Limit Values
Protection according IP:
Ambient temperature °C (operation):
Ambient temperature °C (storage):
Relative air humidity % (operation):
Relative air humidity % (storage):
82
4 x 2 x 0,14 mm² ( 4 x 2 x AWG 26)
6 x 2 x 0,14 mm² ( 6 x 2 x AWG 26)
12 x 2 x 0,14 mm² (12 x 2 x AWG 26)
with interface V 24 (RS-232C) - 3 m (with shielding)
with Centronics - 3 m (with shielding)
with USB - 3 m
with Ethernet - 100 m
20
min. +5 max. +35
min. −20 max. +60
max. 80
max. 80 (bedewing of printers not allowed)