GS620N alarm memory (reset "old" alarms) and sets the
detector to latch mode. No LED indication is possible in this
mode. In latch mode every detector will latch an alarm into the
alarm memory.
The LED enable input selects in which memory the alarm is
stored. If the LED enable input is not activated, the alarm is
stored into the first-to-alarm memory (FTA), indicating this
sensor came into alarm first. When the LED enable input is
activated, the alarm will be latched into the subsequent-to-
alarm memory (STA) indicating the sensor subsequently came
into alarm.
To enable the STA memory function the LED enable input of
the detector can be connected to an alarm latch output of the
control panel, which activates the latch inputs of all detectors
after an alarm (see Figure 2).
When the LED enable input is not connected, the alarms will
always be stored into the First to Alarm memory.
When the system is disarmed, the latch input should be de-
activated.
Any device with an alarm stored into its memory will indicate
this with its LED.
A slow flashing LED indicates a first-to-alarm storage. A steady
"on" LED indicates a subsequent-to-alarm storage. A fast
flashing LED indicates fault detection.
Note:
An activated LED enable input overrules the memory
indication of the device and does not reset the alarm memory
of the device.
The next time the system is armed, the latch input is activated
and the alarm memory of the detector is reset. The LED is
disabled.

Maintenance

Check on a regular base that the GS620N is reporting an
alarm on the control panel when applying an appropriate inertia
signal to the sensor.

Specifications

Supply voltage
Peak to peak ripple
Current consumption:
Normal operation
Alarm (LED off)
No alarm / LED on (memory)
Alarm output
Alarm time
Tamper output
Operating temperature
Weight
Dimensions
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
P/N 1039187 (ML) • REV E • ISS 13JUN19
8 to 15 V (12 V nom.)
2 V max. at 12 V
8.0 mA
2.5 mA
14.5 mA
100 mA at 28 V
min. 3 s
100 mA at 28 V
−10 to +55°C
45 g
93 x 30 x 24 mm
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED
DEALER" OR "AUTHORIZED RESELLER", IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Certification
Housing meets IP30 IK02.
Designed to conform to BS4737.
European Union
UTC Fire & Security hereby declares that this
directives
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU. For more information see
www.utcfireandsecurity.com or
www.interlogix.com.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info
Contact information
www.utcfireandsecurity.com or www.interlogix.com
Customer support: www.interlogix.com/customer-support
DE: Installationsanweisungen
Beschreibung
Abbildung 1: Sensorkopf
Abbildung 2: Standardverwendung (Steckbrücke J2 entfernt)
Abbildung 3: Dual-Schleifen-Verwendung (Steckbrücke J2
gesetzt)
(1) Schrauben des Sensormoduls
(2) J1
(3) LED einschalten
(4) Speichern
(5) Widerstands-konfiguration im Dual-MG Modus
(6) Die Anschlußklemme 4 und 6 nicht anschließen
(7) Einbruchmeldezentrale
(8) J2
(9) Speichern (scharfschalten / unscharfschalten)
(10) LED einschalten
(11) Alarm MG
(12) Sabotage MG
(13) Dual-Meldegruppe
3 / 18

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis