Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Interlogix ATS1210E Installationsanleitung

Vorschau ausblenden Andere Handbücher für ATS1210E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
LEDs
RX: LED flashes to indicate polling data is being received on
the system databus from the ATS control panel. If the LED
does not flash the control panel is not operational or the
databus is faulty (usually cabling).
TX: LED flashes to indicate the DGP is replying to polling from
the ATS control panel. If the RX LED flashes but the TX LED
does not, it indicates that the DGP is not programmed to be
polled in the control panel or that it is addressed incorrectly.
Connecting the data gathering panel to
a control panel
Refer to Advisor Master Installation Guide or Advisor
Advanced ATSx500A Installation and Programming Manual for
instructions.
Zone and output numbering
Zone numbering
ATS1210(L)E / ATS1211E has 8 zones that can be expanded
using ATS1202 (8 zones) to a maximum of 16 zones.
Output numbering
A DGP can have a maximum of 16 outputs available as relays
or open collector outputs. The output numbers are the same as
the 16 zone numbers allocated to the DGP address.
Advisor Master zone and output numbering
Control panel
1–16
DGP1
17–32
DGP2
33–48
DGP3
49–64
DGP4
65–80
DGP5
81–96
DGP6
97–112
DGP7
113–128
Advisor Advanced ATSx500A zone and output numbering
Control panel
1–16
DGP1
17–48
DGP2
49–80
DGP3
81–112
DGP4
113–144
DGP5
145–176
DGP6
177–208
DGP7
209–240
[1]
Inputs 17 to 32 of DGP 15 cannot be used.
See Advisor Advanced ATSx500A Installation and
Programming Manual for more information.
P/N 1077869 (ML) • REV C • ISS 22MAY19
DGP8
129–144
DGP9
145–160
DGP10
161–176
DGP11
177–192
DGP12
193–208
DGP13
209–224
DGP14
225–240
DGP15
241–256
DGP8
241–272
DGP9
273–304
DGP10
305–336
DGP11
337–368
DGP12
369–400
DGP13
401–432
DGP14
433–464
DGP15
465–480 [1] /
465–496
Programming the DGP
DGP menu
ATS1210(L)E / ATS1211E provides a menu through which a
number of options can be set. In addition the status of
ATS1210(L)E / ATS1211E itself or inputs can be viewed. See
Figure 5.
Extended mode
To enable anti-mask detection it is necessary to select
Extended mode. Standard mode is needed for backwards
compatibility. Default is Extended mode.
Configuring Advisor Master control panel
Activate polling ATS1210(L)E / ATS1211E.
1.
Enter menu 4 of the control panel installer menu, and add
the address for the device, then press Enter.
Press Enter, select the "DGP address" and press Enter
2.
again to enter the DGP details.
3.
Select the device type 5 (advanced DGP).
4.
Press Enter until you are back to the main menu.
To enter the programming menu for ATS1210(L)E / ATS1211E
from Advisor Master control panel:
1.
Enter menu 28 of the control panel installer menu.
2.
Press 1 Enter followed by the DGP address selected and
Enter to enter the DGP menu. The display now shows
"ATS121x" followed by the version number.
3.
Press Enter to proceed to the menu or press the menu
number followed by Enter to go to a menu item directly.
For more information on control panel programming, see
Advisor Master Programming Manual.
Configuring Advisor Advanced ATSx500A control panel
1.
Enter Device menu > Edit Rkp&Exp > Exp devices > Add
new.
2.
Enter the expander address (set by DIP switch) and press
Enter.
To enter the programming menu for ATS1210(L)E / ATS1211E
from Advisor Advanced ATSx500A control panel:
1.
Enter Expander devices menu.
2.
Select the appropriate expander by entering its number, or
moving the cursor with arrow keys.
3.
Go to the Expander menu.
For more information on control panel programming, see
Advisor Advanced ATSx500A Installation and Programming
Manual.

Technical specifications

Supply voltage
Current consumption
Data retention
Dimensions (H x W) (size BB board)
10.5 to 13.8 V
(12 V
nom.)
53 mA max.
> 40 years
90 x 80 mm
3 / 24

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ats1210lAts1211e

Inhaltsverzeichnis