8.6.5 Current signal control 0-20 mA / 4-20 mA
For controlling the dosing pump via an external current
signal of 0-20 mA (4-20 mA)
0-20mA
Run
Fig. 23 Input signal: 0-20 mA
4-20mA
Run
Fig. 24 Input signal: 4-20 mA
The stroke frequency is proportional to a current input signal
of 0-20 mA (4-20 mA).
Above 19.8 mA, the pump runs in continuous operation at
maximum stroke frequency.
Below 0.2 (4.2) mA, the pump switches off.
The pump must be started first in this operating
mode (LED lights up green, "Run" appears in the
Note
display).
Use the "Start/Stop" button to start or stop the pump.
4-20 mA current signal control
If the current input signal falls below 2 mA, the error relay is
switched, as an error has probably occurred at the signal source
or on the cable.
The error signal relay switches on, the LED flashes red.
"4-20 mA" and "ERROR" flash in the display.
4-20mA
Run
ERROR
Fig. 25 Display: current input signal < 2 mA
Analog
0
1/min
Analog
0
1/min
Analog
0
1/min