Herunterladen Inhalt Inhalt Diese Seite drucken

Starting Up; Switching Off; Maintenance - Parkside PDTS 6.3 A2 Bedienungs- Und Sicherheitshinweise

Druckluft-trennschleifer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 83
Compressed air supply and connection
Use filtered, lubricated, and regulated
compressed air only. The following figure il-
lustrates the correct way of connecting to the
compressed air system, and tool effective-
ness and life is extended as a result.
Connecting sleeve
Anschlussmuffe
Quick release connector
Pressure regulator
Filter
Oiler
Quick release connector
Before first use and thereafter at regular
intervals, apply a few drops of pneumatic
equipment or motor oil SAE 10-20 into the
compressed air connection on the pneumatic
device. After every 3–4 operating hours, use
the assembly key to remove the screw plug
9
in the oil reservoir. Fill the oil reservoir
with pneumatic equipment or motor oil SAE
10-20, and insert the screw plug back.
Wrap some Teflon sealing tape around the
thread on the air connections. Screw the air
connections into the pneumatic devices.
z Starting up
Put on protective clothing and goggles.
OTHERWISE THERE IS DANGER OF
INJURY!
Check that the parting disc
tightened securely.
Check that the workpiece is supported
Quick release
connector
Compressed air hose
Compressor
6
has been
or has been locked in place correctly.
A C clamp is recommended on loose
workpieces.
Make sure that generated sparks do
not pose any danger, i.e. they cannot
contact any persons or ignite flammable
substances.
Connect the compressed air supply. To
do so, connect the compressed air source
to the compressed air connection
Press the switch ON guard
the chuck. Press the trigger arm
perform the cutting work. The device
rotates at the maximum speed when
the trigger arm
2
stop. Regulate the tightening pressure
and therefore the speed for the optimal
grinding results.
z Switching OFF
Release the trigger arm
pneumatic angle grinder.
After work, disconnect the device from the
compressed air source.
Note: First detach the hose from the com-
pressed air source, and then remove the
supply hose from the device. This prevents
the supply hose from whirling out of control.
z Maintenance
If the machine is to enjoy a long service life
and operate without problems, it is important
that the following maintenance instructions
are followed. The pneumatic angle grinder
must be lubricated regularly if it is to operate
flawlessly at all times.
Operation
1
.
3
towards
2
, and
is tightened to the
2
to switch OFF the
GB/MT
77

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis