16.2 Logging a DuoFern device on/off using a roller shutter switch/button
or universal setting cable
Requirement
The tubular motor must be stopped.
1.
Switch on the mains power.
2.
Activate log-on/off mode for the tubular motor
as follows.
120 seconds
Log-on/off mode remains active
for approx. 120 seconds.
3.
Activate log-on/off mode on the DuoFern device.
Please read the operating manual for the
respective DuoFern device..
4.
The tubular motor acknowledges a successful log-
on/off by starting up briefly.
5.
Log the next DuoFern device on or off, or
end the process.
70
Using a roller shutter
switch/button
OR
ON
A desired direc-
tion of travel
Tap 2 x and press
and hold the third
time until the tu-
bular motor starts
up briefly.
Release/switch off
the button again.
Pay attention to the time remaining until the
DuoFern device is logged-on or off.
EN
With the universal
setting cable
The LED on
ON/
button 3 must
SET
light up
continously.
Direction of
I
travel 1
or
Diréction of
II
travel 2
Switch on/off briefly 2 x
and hold the third time
until the tubular motor
starts up briefly
I
Set the rocker switch to
the centre position.
II
To terminate the
ON/
operation switch off
SET
Button 3 (continuous
phase.)

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis