13. Technical specifications

Motor series:
Plug-in connecting cable (PVC)
Protection type in accordance with VDE
Motor length without bearing
Sound pressure level (LpA)
- indoors (depending on the building structure)
Number of parallel tubular motors that can
(when using RADEMACHER controllers,
14. Configuration of KNX/EIB Venetian blind actuators for
i
RADEMACHER tubular motors
In order to ensure trouble-free operation of
RADEMACHER tubular motors with KNX/EIB
Venetian blind actuators, the following parameters
must be set prior to commissioning:
Transient operation
If possible, transient operation (slat adjustment)
should be switched off.
e.g.
Mode for transient operation
Time: = 0 ms
Nominal torque:
No-load speed
Nominal voltage
Frequency
Nominal power
Current consumption
On-period (KB)
Number of wires
Core cross section
End switching range:
(number of revolutions.)
Insulation class
Protection class
700
Tube diameter
Transmission frequency
Max. transmission power
Range approx.
- outdoors
be connected in parallel
e.g. Troll Comfort)
SLDS xx/xx
PZ
Nm
6
10
rpm
28
16
V
230
230
Hz
50
50
W
121
121
A
0.53
0.53
min.
4
4
5
5
mm
0.75
0.75
2
m
2.5
2.5
rev.
112
64
H
H
I
I
IP 44
IP 44
mm
485
485
mm
35
35
dB(A)
≤ 70
≤ 70
MHz
434.5
434.5
mW
10
10
m
30
30
m
100
100
3
3
If transient operation cannot be deactivated
from within the software application...
...then you must ensure that the time between
transient operation and long-term operation on the
key sensor is less that the time between transient
operation and long-term operation on the actuator.
This will ensure that transient switch-off of the actua-
tor is prevented when holding the sensor key down.
Long-term operation
The motor must be switched off at the latest after
180 seconds.
e.g.
Basis for long-term operation
Basis:
Factor: = 86
SLDM xx/xx
PZ
10
20
30
16
16
16
230
230
230
50
50
50
112
145
191
0.49
0.64
0.83
4
4
4
5
5
5
0.75
0.75
0.75
2.5
2.5
2.5
64
64
64
H
H
H
I
I
I
IP 44
IP 44
IP 44
IP 44
487
487
546
45
45
45
≤ 70
≤ 70
≤ 70
434.5
434.5
434.5
434.5
10
10
10
30
30
30
100
100
100
2
2
2
= 2.1 s
= (2.1 s x 86 = 180.6 s)
EN
40
50
16
12
230
230
50
50
198
205
0.86
0.89
4
4
5
5
0.75
0.75
2.5
2.5
64
48
H
H
I
I
IP 44
546
546
45
45
≤ 70
≤ 70
434.5
10
10
30
30
100
100
2
2
67