Positioning and levelling
The positioning and electrical and gas installation should always be carried out by an AUTHORISED TECHNICIAN,
observing the standards of each country.
It is advisable to install an extraction hood for the optimum operation of the appliance.
Put the appliance in a sufficiently ventilated room, in accordance with the current regulations, to prevent the formation
of unacceptable concentrations of harmful substances in its installation site.
IMPORTANT: Except when indicated otherwise, the parts that must be protected by the manufacturer must not be
manipulated by the installer.
Level and adjust the height of the appliance. (Fig. 1)
Electrical connection
The appliance's electrical connection should always be carried out by an AUTHORISED TECHNICIAN.
The legal standards in force in each country on connections to the mains should be taken into account.
Check that the mains voltage corresponds to that indicated on the name plate.
Use cable sleeves made out of polychloroprene or other similar materials (H05RN-F), for the connection.
Put an autonomous power switch with fuses into the mains socket, with a minimum distance between contacts of at
least 3 mm.
It is obligatory to earth the appliance. The manufacturer takes no responsibility if this requirement is not fulfilled.
The section of cable sleeve and the rating of the fuses to be installed in the power switch are indicated in table no. 2.
To access the appliance's electrical connection terminal strip (see fig 2), loosen the screws (4) on the lid of the
switchboard (2). Pass the cable sleeve through the stuffing box located in the switchboard and connect it to the
terminal strip.
VERY IMPORTANT: Before putting the switchboard top on, fasten the electric supply cable tightly to the stuffing box.
When several appliances are installed in series, they should be earthed to each other using the point assigned for
this purpose, located in the rear part of the appliance.
Gas connection
The general installation should have a stop-cock and a pressure regulator and it also advisable to install a shut-off
cock on each individual appliance.
A tube of at least Ø 12 x 10 mm should be used for the appliance's gas connection, along with a ¾" nut to put the
fryer together Fig. 1- Fig. 1 bis
Conversion to different gases
If the appliance is prepared for a different type of gas to the one available, you should proceed as follows:
Cut off the gas to the appliance if connected. (All conversions of the appliance's gas circuit must always be carried
out by a QUALIFIED TECHNICIAN).
Burner conversion
Injector replacement.
Dismantle the burners' "I" injectors (Fig. 3) and replace them with suitable ones depending of the gas to be used
(Table 5)
Burner air adjustment.
Set the air regulator "R" (Fig. 3) to the "H" measurement (Table 5) depending on the gas to be used.