Herunterladen Inhalt Inhalt Diese Seite drucken

Extended Menu - Seav LR 2212 Bedienungsanleitung

Elektronische steuereinheit
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22

EXTENDED MENU 2

The control unit is supplied by the manufacturer with the option of directly selecting
only the functions listed in the main menu.
To enable the functions of Extended menu 2, proceed as follows: access Extended
menu 1 (as described in the corresponding paragraph), then press the SET button
again and hold for 5 seconds. After this time period has elapsed, the T. PAUSA and RIT.
ANTE LEDs will begin to flash. The user has a period of 30 seconds in which to select
the functions of Extended menu 2 using the SEL and SET buttons; after a further 30
seconds the control unit returns to the main menu.
EXTENDED MENU 2
Reference LED
LED Off
A) 1-2 MOTORS
remote PGM = OFF
B) AUT / P-P
photocells test = OFF
C) CODE
flashing/courtesy light = OFF flashing/courtesy light = ON
D) PED. CODE
pause flashing = OFF
E) T. MOT. PED.
El. Lock CMD = OFF
F) T.MOT.PED.
PUL=PUL - PED=PED
G) T. PAUSA
simultaneous ON/OFF flashing
H) RIT. ANTE
simultaneous ON/OFF flashing
A) 1 – 2 MOTORS
(remote programming of radio control):
The control unit allows the transmission code to be programmed by remote, without
using the SEL key.
To programme the radio control remotely, proceed as follows: send the radio control
code continuously for more than 10 seconds and the control unit will enter the pro-
gramming mode as described above for the CODE LED in the main menu.
The control unit is supplied by the manufacturer with remote programming of the trans-
mission code not enabled; to enable the function proceed as follows: make sure that
Extended menu 2 is enabled (T. PAUSA and RIT. ANTE LEDs flash simultaneously), use
the SEL button to navigate to 1-2 MOTORS LED when flashing and press the SET but-
ton: the 1-2 MOTORS LED switches on and programming is complete. Repeat the pro-
cedure to restore the previous configuration.
B B) AUT / P-P (Photocells Test):
The control unit is supplied by the manufacturer with the Photocells Test programming
deactivated; if wanting to enable such function (in compliance with Standard EN 12453)
it is firstly necessary to move the jumper located on the board from position 1-2 to posi-
tion 2-3. If wanting to enable the test only on DS1, proceed as follows: ensure to have
enabled Extended Menu 2 (highlighted by the simultaneous flashing of PAUSE T. LED
and DOORS DEL. LED), with the SEL key positioned on the flashing of AUT/S-S LED
press the SET key, the AUT/S-S LED will simultaneously switch on permanently and the
programming is completed. In this way, the DS1 test will be carried out before automa-
tion starts any movement. If wanting to enable the test for both photocells (DS1 and
LED On
remote PGM = ON
photocells test = ON
pause flashing = ON
El. Lock CMD = ON
PUL=AP - PED=CH
- 12 -
DS2), repeat the operation described above, pressing the SEL key twice (obtaining the
quick flashing of AUT/S-S LED) instead of once. In this way, the test on both photocells
will be carried out before automation starts any movement.
Repeat the operation if wanting to restore the previous configuration. If not used, inputs
DS1 and DS2 must be linked up using jumpers and the Photocells Test deactivated.
Important: ensure the appropriate jumper is positioned correctly, in accordance or not,
with the programming of the Photocells Test.
C) CODE (advance flashing / courtesy light):
The control unit is supplied by the manufacturer with the advance flashing and cour-
tesy light functions disabled. To enable the advance flashing function proceed as fol-
lows: make sure that Extended menu 2 is enabled (T. PAUSA and RIT. ANTE LEDs flash
simultaneously), use the SEL button to navigate to CODE LED when flashing and press
the SET button: the CODE LED switches on and programming is complete. To enable
the courtesy light function, repeat the procedure above, pressing the SEL button twice
(the CODE LED flashes rapidly) instead of once. Repeat the procedure to restore the
initial configuration.
Advance flashing operation: The 230 V a/c flashing beacon output will always be
enabled 3 seconds before the automation begins moving in any direction.
Courtesy light operation: The 230 V a/c flashing beacon output will be enabled for 3
minutes every time an opening command is given.
D) PED. CODE (flashing beacon operation):
The control unit is supplied by the manufacturer with the flashing beacon function dur-
ing pause time disabled. To enable the function proceed as follows: make sure that
Extended menu 2 is enabled (T. PAUSA and RIT. ANTE LEDs flash simultaneously), use
the SEL button to navigate to the PED. CODE LED when flashing and press the SET
button: the PED. CODE LED is illuminated in a constant manner and programming is
complete. Repeat the procedure to restore the previous configuration.
E) T. MOT (electric lock PED. CMD activation):
The control unit is supplied by the manufacturer with the electric lock pedestrian com-
mand function disabled. To enable the function proceed as follows: make sure that
Extended menu 2 is enabled (T. PAUSA and RIT. ANTE LEDs flash simultaneously), use
the SEL button to navigate to the T. MOT. LED when flashing and press the SET but-
ton: the T. MOT. LED remains lit in a constant manner and programming is complete.
The electric lock pedestrian command function is used when, for example, a sliding
gate has been fitted with a door for pedestrian passage next to it. This means the gate
can be opened using the PUL commands and the pedestrian door can be opened by
enabling the electric lock function using the PED commands. Repeat the procedure to
restore the previous configuration.
F) T. MOT. PED. (PUL and PED commands operation):
The control unit is supplied by the manufacturer with an enabled PUL command input
for the connection of a cyclical main command button (NA) and PED input for the con-

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Lrx 2212Lg 2212Lrs 2212Lrs 2212 setLrh 2212

Inhaltsverzeichnis