MPORTANT
Before gate automation, it is necessary to check the product is in good condition
and that it complies with EN 12604 and the Machines Directive.
The control unit does not have any type of isolating device for the 230 Vac line. It will
therefore be the responsibility of the installer to arrange an isolating device inside the
plant. It is necessary to install a single-phase switch with over-voltage category III. It
must be positioned where it can be protected from accidental closing, according to
that prescribed in point 5.2.9 of EN 12453. The wiring of external electrical compo-
nents must comply with EN 60204-1 as amended in section 5.2.7 of EN 12453. The
power supply cables can have a maximum diameter of 14 mm; the fixing of the
power supply and connection cables must be guaranteed through the assembly of
available cable glands "optional".
For the power supply cables, use flexible cables under insulating sheath in har-
monised polychloroprene (H05RN-F) with minimum section of the conductors equal
to 1mm2
The rear casing is designed for wall installation (it is designed to have holes so
that it may be installed using rawl plugs, or so that it can be fixed in place using
screws). Plan and apply all the details necessary for the IP degree to remain unal-
tered after installation.
If present, the keypad for manual control must be mounted in such a way that the
user is not placed in a dangerous situation.
The motor reducer used to move the gate must comply with section 5.2.7. of EN
12453.
The D.S. power supply output must be dedicated to the powering of photoelectric
cells. It must not be used for other purposes.
The control unit tests the operation of photoelectric cells at every manoeuvring cycle
to guarantee protection against failures of Category 2 anti-crushing devices, in com-
pliance with section 5.1.1.6 of EN 12453. Therefore, if the safety devices are not
connected and/or operated, the control unit is not enabled for operation.
For the radio receiver to operate correctly when two or more control units are used,
we recommend that you install the devices at least 3 metres away from each other.
The below products:
Electronic Control Unit:
LG 2212 - LRS 2212 - LRS 2212 SET - LRH 2212
conform to the specifications in the Directives
RED 2014/53/EU, EMC 2014/30/EU, LVD 2014/35/EU.
Rev. 3.0 13/06/2016
- 14 -

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Lrx 2212Lg 2212Lrs 2212Lrs 2212 setLrh 2212

Inhaltsverzeichnis