Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Seav LR 2212 Bedienungsanleitung

Elektronische steuereinheit
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
ELECTRONIC CONTROL UNIT LRX 2212
Single-phase electronic control unit for the automation of swinging and sliding gates,
with incorporated radio receiver.
- Mod. LG 2212
- Mod. ( LR
2212 )
- Mod. ( LRS 2212 / 330 )
- Mod. ( LRS 2212 / 418 )
- Mod. LRS 2212
- Mod. LRS 2212 SET
- Mod. LRH 2212
( ) Product intended for those countries where its use is permitted

TECHNICAL DATA:

- Power supply
- Flashing beacon output
- Motor outputs
- Electric lock output
- Photoelectric cells power supply
- Indicator light output
- Low voltage safety features and commands
- Operating temperature
- Radio receiver
- Op. transmitters
- Max stored TX codes
- Container size
- Protection degree
TERMINAL BOARD CONNECTIONS:
CN1:
1 : Earth connection.
2 : Earth connection.
3 : Earth connection.
CN2:
1 : 230 V a/c line input (Phase).
2 : 230 V a/c line input (Neutral).
3 : 230 V a/c Flashing beacon output (Neutral).
4 : 230 V a/c Flashing beacon output (Phase).
5 : Motor 1 opening output.
6 : Motor 1 shared output.
7 : Motor 1 closing output.
8 : Motor 2 opening output.
9 : Motor 2 shared output.
10 : Motor 2 closing output.
: Without radio receiver
: 306 MHz
: 330 MHz
: 418 MHz
: 433.92 MHz
: 433.92 MHz "narrow band"
: 868.3 MHz "narrow band"
: 230 V a/c 50-60 Hz 1600 W max.
: 230 V a/c 500 W max.
: 230 V a/c 500 W max.
: 12 V d/c 15 W max.
: 24 V a/c 5 W max.
: 24 V d/c 4 W max.
: 24 V d/c
: -10 ÷ 55 °C
: see model
: 12-18 Bit or Rolling code
: 120 (CODE or PED. CODE)
: 240 x 185 x 110 mm.
: IP 65
CN3:
1 : 12 V d/c 15 W (+12 V) Electric lock output.
2 : 12 V d/c 15 W (GND) Electric lock output.
3 : Photoelectric cell control and power supply (24 V a/c 5 W).
4 : Photoelectric cell control and power supply (GND).
5 : Indicator light output (+24 V d/c 4 W).
6 : Indicator light output (GND).
7 : Open / close command button input (NA).
8 : Pedestrian / single gate / close command button input (NA).
9 : Shared GND input.
10: Lock input (NC).
11: Safety device 1 input (NC).
12: Shared GND input.
13: Safety device 2 input (NC).
14: Opening stop limit input (NC).
15: Shared GND input.
16: Closing stop limit input (NC).
17: Earth antenna input.
18: Antenna hot pole input.
OPERATIONAL DATA:
Automatic operation:
Using both the radio control (CODE LED illuminated) and the low voltage keypad (PUL)
to control the gate, the following operation is obtained:
the first press opens the gate until the motor timer reaches zero or until the opening
stop limit is reached, the second press closes the gate; if a button is pressed before
the motor time has elapsed or before one of the two opening stop limits have been
reached, the control unit inverts motion during both opening and closing.
Step-by-step operation:
Using both the radio control (CODE LED illuminated) and the low voltage keypad (PUL)
to control the gate, the following operation is obtained:
the first press opens the gate until the motor timer reaches zero or until the opening
stop limit is reached, the second press closes the gate; if a button is pressed before
the motor time has elapsed or before one of the two opening stop limits have been
reached, the control unit stops motion during both opening and closing. A further com-
mand restarts motion in the opposite direction.
Automatic closing:
The control unit can close the shutter automatically without sending additional com-
mands.
The selection process for this operating mode is described in the Pause Time program-
ming mode.
Pedestrian passage:
The control unit can operate motor 1 only using both the radio control (CODE LED on)
and the keypad (PED), for the programmed time (T. MOT. PED. LED).