Herunterladen Inhalt Inhalt Diese Seite drucken

Seav LR 2212 Bedienungsanleitung Seite 13

Elektronische steuereinheit
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
nection of a cyclical pedestrian command button (NA). If you wish to select a different
operating mode for the PUL and PED inputs, proceed as follows: make sure that
Extended menu 2 is enabled (T. PAUSA and RIT. ANTE LEDs flash simultaneously), use
the SEL button to navigate to the T. MOT. PED. LED when flashing and press the SET
button: the T. MOT. PED. LED remains lit constantly and programming is complete.
This means the PUL input will allow connection of a button (NA) only for the opening
movement and the PED input will be used for the connection of a button (NA) only for
the closing movement. Repeat the procedure to restore the previous configuration.
EXTENDED MENU 3
The control unit is supplied by the manufacturer with the direct selection possibility of
only the main menu functions.
If wanting to enable the programming of the slowing power carried out by the control
unit, proceed as follows: access Extended Menu 2 (as described in the relative para-
graph), and again press the SET key continuously for 5 seconds, after this time a flash-
ing, firstly alternating then simultaneously, of the PAUSE T. LED and DOORS DEL. LED,
will be obtained; in this way, there are 30 seconds to select the desired slowing using
the SEL and SET keys, then, after a further 30 seconds, the control unit returns to the
main menu.
EXTENDED MENU 3
Level
LEDS Swtiched on
1
1-2 MOTORS
2
1-2 MOTORS - AUT / S-S
3
1-2 MOTORS - AUT / S-S - CODE
4
1-2 MOTORS - AUT / S-S - CODE - PED. CODE
5
1-2 MOTORS - AUT / S-S - CODE - PED. CODE - MOT. T.
6
1-2 MOTORS - AUT / S-S - CODE - PED. CODE - MOT. T. - PED. MOT. T.
Slowing Programming
The control unit allows to program the power at which the slowing phase will be car-
ried out.
It is possible to choose from 6 different power level as follows: at every combination of
switched on LEDS corresponds a level according to the above table; basically, starting
from the lowest LED (LED 1-2 MOTORS) moving upwards, every LED corresponds to
a higher power level. Using the SEL key it is possible to scroll the different power lev-
els; for every selected power level, the highest respective LED flashes (for example, if
level 4 is selected, LEDS 1-2 MOTORS, AUT/S-S- and CODE are switched on perma-
nently, whereas the PED CODE LED flashes); press SET to confirm.
Level 3 is selected in default configuration.
RESET:
To restore the default configuration, press the SEL and SET buttons simultaneously; all
RED LEDs will light up and then switch off.
DIAGNOSTICS:
Photoelectric cells test:
The control unit is set up for the connection of safety devices compliant with 5.1.1.6
section of EN 12453. The operation test for connected photoelectric cells is performed
at each manoeuvring cycle. If there is no connection and/or no operation, the control
unit will not enable motion and will indicate test failure visually through the simultane-
ous flashing of all LEDs. Once the correct functioning of the photoelectric cells has
been restored, the control unit is ready for normal operation. This guarantees monitor-
ing against failures in compliance with Category 2 of EN 954-1.
Command input test:
The control unit is fitted with an LED for every low voltage command input so that the
status may be checked immediately.
Operating principle: LED on = input closed, LED off = input open.
F
U
- I
OR THE
SER
MPORTANT
- The device should not be used by children or by individuals with reduced physical
or psychological abilities unless supervision is provided or instruction given on how
to operate it.
- Do not let children play with the device; keep radio controls out of their reach.
- CAUTION: Keep this instruction manual in a safe place and adhere to the impor-
tant safety instructions contained within it. Non-adherence to these instructions may
lead to property damage and serious accidents.
- Examine the system frequently to check for any signs of damage. Do not use the
device if it needs to be repaired.
Warning
All procedures which require the casing to be opened (such as wire connection, pro-
gramming, etc.) must be carried out during installation, by skilled staff only. For any
other procedure which requires the casing to be opened again (re-programming,
repairs or site modifications), please contact the technical assistance service.