paused). To enable the flashing beacon function, proceed as
follows: use the SEL button to navigate to LAMP/CORT when
the corresponding LED is flashing, then press the SET button:
the LAMP/CORT. LED lights up and remains constant.
Repeat the operation to restore the default configuration.
To enable the courtesy light, repeat the operation above, by
pressing the SEL button twice (LAMP/CORT LED flashes
rapidly) instead of once. Repeat the operation to restore the
default configuration.
Flashing beacon function while the unit is paused:
The 230 V a/c output will activate every time automation takes
place, for the duration of the motor timer. If the Pause Time is
stored, the 230 V a/c output will also be active during the
Pause.
Flashing Beacon operation:
activate every time automation takes place, for the duration of
the motor timer.
Courtesy Light operation: The 230 V a/c output will activate
for 3 minutes every time an opening command is given.
5) T. MOT:
(Programmed motor operation time: max. 4 minutes)
The control unit is supplied by the manufacturer with the
Automatic Motor Timer enabled, this way the control unit
removes the power supply from the motor 1 second after it has
reached the internal stop limit of the motor. If there is an
established motor operation time and an Automatic Motor Timer
which is disabled, proceed as follows when the shutter is closed
to perform the programming process: use the SEL button to
reach the stage where the T. MOT LED flashes, then press the
SET button briefly; the Motor will begin the Opening cycle.
When the shutter reaches the desired position press the SET
button. The motor time is stored and the T. MOT. LED remains
lit in a constant manner.
To restore the initial configuration (with the Automatic Motor
Timer function enabled) navigate to the stage where the T.
MOT. LED is flashing then press the SET button twice within 2
seconds; the LED switches off and the operation is complete.
During programming the radio control button on the control unit
can be used instead of the SET button, if stored previously.
6) T. PAUSA:
(Programmed aut. closing time: max. 4 min.)
The control unit is supplied by the manufacturer without an
automatic closing procedure. To enable the automatic closing
function, proceed as follows: use the SEL button to reach the
stage where the T. PAUSA LED is flashing, then press the SET
button, wait for the desired pause time, then press the SET
button again for a moment; the automatic closing time is stored
and the T. PAUSA LED remains lit in a constant manner.
To restore the initial configuration (without automatic closing)
navigate to T.PAUSA when the corresponding LED is flashing
then press the SET button twice within 2 seconds; the LED
switches off and the operation is complete.
During programming the radio control button on the control unit
can be used instead of the SET button, if stored previously.
7) SEL IN1 - 2:
(Selection of IN1 – IN2 operation)
The control unit is supplied by the manufacturer with the
following IN1 and IN2 input selection: input IN1 is used for the
connection of a cyclical "P/P" command button (NA) and input
IN2 for the connection of a general safety device DS1 with
contact (NC).
If you wish to select a different operating mode for inputs IN1
and IN2, proceed as follows: use the SEL button to reach a
stage where the SEL INPUT 1-2 LED is flashing and press the
SET button: the SEL INPUT 1-2 LED lights up in a constant
manner and programming is complete. The IN1 input thus
becomes the button connection (NA) solely for the "UP" opening
phase and IN2 becomes the button connection (NA) solely for
the "DOWN" closing phase. Repeat the operation to restore the
previous configuration.
The 230 V a/c output will

EXTENDED MENU

The control unit is supplied by the manufacturer with the option
of selecting only the functions listed in the main menu.
To enable the functions of the extended menu proceed as
follows: press and hold the SET button for 5 seconds; the
T.PAUSA and SEL INPUT LEDs will flash alternately and the
user has 30 seconds within which to select the functions of the
extended menu using the SEL and SET buttons. After another
30 seconds the control unit returns to the main menu.
---------------------- EXTENDED MENU -----------------
Reference LED
A) AUT/MANUAL
Step-by-Step
B) CODE
remote PGM = OFF
C) INB.CMD.AP.
Test DS1 – DS2 = OF
ON
D) LAMP/CORT
DS1 = INV in closure
E) T.MOT
IN3 = FCAP - IN4 = FCCH
DS3
F) T. PAUSA
G) SEL INPUT 1 - 2
A) AUT/MANUAL (Step-by-Step /Inverting operation):
The control unit is supplied by the manufacturer with the
Inverting operation mode disabled. To enable the function
proceed as follows: check that the extended menu is enabled
(T.PAUSA and SEL INPUT 1-2 LEDs start flashing alternately),
use the SEL button to navigate to the AUT/MANUAL LED when
it is flashing and press the SET button: the AUT/MANUAL LED
lights up and programming is completed.
In this mode, using both the radio control and the low voltage
keypad to control the gate, the following operation is obtained:
the first press opens the gate until the end of the motor time, the
second press closes it; if a button is pressed before the end of
the motor running time, the control unit inverts motion both
during opening and closing. Repeat the operation to restore the
previous configuration.
B) CODE
(Remote programming of radio control):
The control unit allows the transmission code to be
programmed by remote, without using the SEL button.
To programme the transmission code remotely, proceed as
follows: send a code, continuously and for a period of longer
than 10 seconds, from a radio control stored previously: the
control unit enters its programming mode as described
previously for the CODE LED in the main menu.
The control unit is supplied by the manufacturer with remote
programming of the transmission code not enabled; to enable
the function proceed as follows: check that the extended menu
is enabled (the T.PAUSA and SEL INPUT 1-2 LEDs flash
alternately), using the SEL button navigate to CODE LED when
flashing and press the SET button: the CODE LED lights up and
programming is completed. Repeat the operation to restore the
previous configuration.
C) INB. CMD. AP
(Photoelectric cells DS1 and DS2 operation test):
The control unit is supplied by the manufacturer with the
photoelectric cells test disabled; if you wish to enable the
function (in compliance with EN 12453), proceed as follows:
check that the extended menu is enabled (T.PAUSA and SEL
INPUT 1-2 LEDs flash alternately), using the SEL button
navigate to INB.CMD.AP LED when flashing and press the SET
button: the INB.CMD.AP LED lights up and programming is
completed. This is how the photoelectric cells test for the safety
inputs (inversion during closure) defined as DS1 and DS2 is
8
LED Off
LED On
Inverting
remote PGM = ON
Test DS1 – DS2 =
DS1 = Lock
IN3 = DS2 - IN4 =
Flashing beacon ON/OFF
Flashing beacon ON/OFF
Rev. 3.0
13 – 06 - 2016