Automatic / Step-By-Step - Seav LR 2212 Bedienungsanleitung

Elektronische steuereinheit
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
necessary, it is possible to position the motor 1 and motor 2 outputs in parallel in order
to double the applicable load (one motor up to 1.5 CV).

2) AUTOMATIC / STEP-BY-STEP:

The control unit is supplied with the "Automatic" operation feature enabled by default
(AUT/P-P LED off). To enable the "step-by-step" operation feature (AUT/P-P LED on)
proceed as follows: use the SEL button to navigate to AUT/P-P LED when flashing and
press the SET button: the AUT/P-P LED lights up. Repeat the procedure to restore the
previous configuration.
3) CODE: (Radio control code)
The control unit can store up to 150 radio controls with different fixed or rolling codes.
Programming.
To programme the transmission code, proceed as follows: use the SEL button to reach
a point where the CODE LED is flashing and send the desired code using the relevant
radio control; programming has been completed when the CODE LED remains lit con-
stantly. If you have stored 120 codes and you repeat the programming procedure, all
the programming LEDs will start flashing to indicate that no more codes can be stored.
Deleting the codes.
To delete all transmission codes stored in the memory, proceed as follows: press the
SEL button; the CODE LED will start flashing. Then press the SET button: the CODE
LED will switch off and the procedure will be complete.
4) PED. CODE:(radio control code for Ped. / Left Door)
The programming and deleting procedure is the same as the one illustrated above, with
reference to the PEDESTRIAN CODE LED.
5) MOTOR TIME and DECELERATION: (Programming a motor operation time of max.
4 minutes)
The control unit is supplied by the manufacturer with the default motor operation time
of 30 seconds without deceleration.
To modify the operating time of motors 1 and 2, perform this procedure while the gate
is closed: use the SEL button to reach the stage where the T. MOT LED flashes, then
press the SET button briefly; the motor will begin the opening cycle. When the shutter
reaches the desired initial position press the SET button. The T. MOT LED will begin
flashing more slowly and motor 1 will slow down; when the desired position has been
reached press the SET button to conclude the opening cycle. At this point the T. MOT
LED will begin flashing normally again and motor 2 will begin its opening phase: repeat
the operating time programming procedure for motor 2. Once the opening phase motor
times have been programmed, motor 2 begins its closing phase immediately. Repeat
the above steps for the closing phase of motor 2 and then motor 1.
To deactivate the deceleration function during programming, once the opening and
closing cycles are complete, press the SET button twice in succession instead of just
once.
If the control unit is used in the 1-motor configuration (1-2 MOTORS LED OFF), the
operating time for motor 2 will not be programmed.
During programming the radio control button on the control unit can be used instead
of the SET button, if stored previously.
6) T. MOT. PED.: (Programming pedestrian operation time of max. 4 minutes)
The control unit is supplied by the manufacturer with a default motor 1 operation time
(pedestrian) of 10 seconds, without deceleration.
To modify the pedestrian operation time, perform this procedure while the gate is
closed: use the SEL button to reach the stage where the T. MOT. PED. LED flashes,
then press the SET button briefly; the motor will begin the opening cycle. When the
shutter reaches the desired initial position press the SET button. The T. MOT. PED. LED
will begin flashing more slowly and motor 1 will slow down; when the desired position
has been reached press the SET button to conclude the opening cycle. At this point
the T. MOT. PED. LED will begin flashing normally again and motor 1 will start running
again in its closing direction; repeat the abovementioned steps for the closing phase.
To deactivate the deceleration function during programming, once the opening and
closing cycle is completed, press the SET button twice in succession instead of just
once.
During programming the radio control button on the control unit can be used instead
of the SET button, if stored previously.
7) T. PAUSA: (Programmed aut. closing time: max. 4 min.)
The control unit is supplied by the manufacturer without an automatic closing proce-
dure. To enable the automatic closing function, proceed as follows: use the SEL button
to navigate to T. PAUSA when flashing, then press the SET button, wait for the desired
interval of time, then press the SET button again; the automatic closing time will be
stored and the T.PAUSA LED will be lit. To restore the initial configuration (without auto-
matic closing) navigate to T.PAUSA when the corresponding LED is flashing then press
the SET button twice within 2 seconds. The LED will switch off and the procedure will
be complete.
During programming the radio control button on the control unit can be used instead
of the SET button, if stored previously.
8) T. RIT. ANTE: (Programming gate delay of max. 15 sec.)
The control unit is supplied by the manufacturer without gate delay during opening and
closing. If the 2-motor automation configuration is used, it may be necessary to enter
a gate delay time; programming must be performed when the gate is closed, in the fol-
lowing manner: use the SEL button to reach the point where the RIT. ANTE LED flash-
es and press the SET button briefly; wait for the desired interval of time, then press the
SET button briefly again; the fixed gate opening delay time of 2 seconds will be stored.
The programmed gate closing delay time will be stored and the RIT. ANTE LED will
remain lit in a fixed manner. To restore the initial configuration (without gate delay) nav-
igate to the RIT. ANTE LED when flashing then press the SET button twice within 2 sec-
onds; the LED switches off and the operation is complete.
- 10 -

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Lrx 2212Lg 2212Lrs 2212Lrs 2212 setLrh 2212

Inhaltsverzeichnis