Herunterladen Inhalt Inhalt Diese Seite drucken

Seav LR 2212 Bedienungsanleitung Seite 11

Elektronische steuereinheit
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
EXTENDED MENU 1
The control unit is supplied by the manufacturer with the option of directly selecting
only the functions listed in the main menu.
To enable the functions of Extended menu 1, proceed as follows: press and hold the
SET button for 5 seconds; the T. PAUSA and RIT. ANTE LEDs start flashing alternate-
ly; the user has a period of 30 seconds in which to select the functions of Extended
menu 1 using the SEL and SET buttons; after 30 seconds the control unit returns to the
main menu.
EXTENDED MENU 1
Reference LED
LED Off
A) 1-2 MOTORS
INB. CMD AP = OFF
B) AUT / P-P
electronic brake = ON
C) CODE
pressure maint. = OFF
D) PED. CODE
ramming effect = OFF
E) T. MOT.
closure strike = OFF
F) T.MOT.PED.
SOFT START = OFF
G) T. PAUSA
alternate ON/OFF flashing
H) RIT. ANTE
alternate ON/OFF flashing
A) 1 – 2 MOTORS
(command inhibition during opening and pause time, if entered):
The command inhibition function during opening and pause time, if entered, is used
when the automation includes the loop detector. During opening or pause time the con-
trol unit does not pick up the commands given by the loop detector at every passage.
The control unit is supplied by default with the command inhibition function during
opening and pause time not enabled. To enable the function proceed as follows: make
sure that Extended menu 1 is enabled (T. PAUSA and RIT. ANTE LEDs flash alternate-
ly), use the SEL button to navigate to 1-2 MOTORS LED when flashing and press the
SET button: the 1-2 MOTORS LED switches on and programming is complete. Repeat
the procedure to restore the previous configuration.
B) AUT / P-P (electronic brake):
The control unit is supplied by the manufacturer with the electronic brake function dis-
abled. To enable the function proceed as follows: make sure that Extended menu 1 is
enabled (T. PAUSA and RIT. ANTE LEDs flash alternately), use the SEL button to navi-
gate to the AUT/P-P LED when flashing and press the SET button: the AUT/P-P LED
will remain lit in a fixed manner and programming will be complete.
The control unit reduces the forward motion of the gate due to inertia in the presence
of a stop or inversion command. Repeat the procedure to restore the previous config-
uration.
C) CODE (maintaining hydraulic motor pressure):
The control unit is supplied by the manufacturer with the hydraulic motor pressure
maintenance feature disabled. To enable the function proceed as follows: make sure
LED On
INB. CMD AP. = ON
electronic brake= OFF
pressure maint. = ON
ramming effect = ON
closure strike = ON
SOFT START = ON
- 11 -
that Extended menu 1 is enabled (T. PAUSA and RIT. ANTE LEDs flash alternately), use
the SEL button to navigate to the CODE LED when flashing and press the SET button:
the CODE LED switches on and programming is complete. This means the control unit
will send a closing command to the motor for 2 seconds, every 2 hours. Repeat the
procedure to restore the previous configuration.
D) PED. CODE (ramming effect):
The control unit is supplied by the manufacturer with the ramming effect function dis-
abled. If you wish to enable the ramming effect function at its maximum power, pro-
ceed as follows: make sure that Extended menu 1 is enabled (T. PAUSA and RIT. ANTE
LEDs flash alternately), use the SEL button to navigate to the PED. CODE LED when
flashing and press the SET button: the PED. CODE LED is illuminated in a constant
manner and programming is complete. To enable the ramming effect function at the set
power using the Trimmer VR1, repeat the above procedure, pressing the SEL button
twice (the PED. CODE LED flashes rapidly) instead of once. Repeat the procedure to
restore the initial configuration.
In this mode the lock can be unlocked and the opening operation phase can be per-
formed correctly. Before starting the opening phase the control unit will send a closing
command for 2 seconds, at a power level which corresponds to the selected value.
E) T. MOT. (closure strike):
The control unit is supplied by the manufacturer with the closure strike function dis-
abled. If you wish to enable the closure strike function at its maximum power, proceed
as follows: make sure that Extended menu 1 is enabled (T. PAUSA and RIT. ANTE LEDs
flash alternately), use the SEL button to navigate to the T. MOT. LED when flashing and
press the SET button: the T. MOT. LED remains lit in a constant manner and program-
ming is complete. To enable the closure strike function at the set power using the
Trimmer VR1, repeat the above procedure, pressing the SEL button twice (the T. MOT
LED flashes rapidly) instead of once. Repeat the procedure to restore the initial config-
uration.
If deceleration during closing is programmed, the control unit will add 1 second at a
power level corresponding to the set value (after the decelerated closing procedure has
been completed) in order to overcome the lock, if present.
F) T. MOT. PED. (SOFT START):
The control unit is supplied by the manufacturer with the soft start function disabled.
To enable the function proceed as follows: make sure that Extended menu 1 is enabled
(T. PAUSA and RIT. ANTE LEDs flash alternately), use the SEL button to navigate to the
T. MOT. PED. LED when flashing and press the SET button: the T. MOT. PED. LED
remains lit constantly and programming is complete. This means the control unit, every
time the motor starts, will control the start-up speed of the motor, gradually increasing
its power from minimum to maximum in the first 2 seconds of operation. Repeat the
procedure to restore the previous configuration.