SAV 2000
533
SAV 4000
588
SAV 6000
738
SAV 9000
818

TECHNICAL DATA

Phase / Voltage
Power
Current
Speed
Max. air temperature
Capacitor
Protection class
Wiring diagram
Speed controller
IMPROPER OPERATION AND REPAIR
Fault removal works shall be performed only by trained and qualified personnel.
Before start of repair works, ENSURE THAT the unit is connected from the supply voltage and wait until the fan motor stops and the heater cools
down.
Follow the above safety requirements.
When the unit switches-off:
Check if voltage and current of the mains correspond to the requirements indicated in the product label.
Check for power availability to the unit.
Upon elimination of power supply faults, switch-on the unit again.
When the fan does not rotate:
When the fan motor has stopped because of overheating and the external protection is activated:
Allow the motor to cool down for 15–20 minutes.
Eliminate the cause for motor overheating.
Switch the fan again.
When the fan does not switch again:
Disconnect the supply voltage.
Wait unit any mechanical movement stops, the motor cools down and the connected capacitors discharge.
Ensure that the impeller is not blocked.
Inspect the capacitor (for single-phase fans – according the connection diagram). If faults repeat, change the capacitor.
Decreased air flow:
Check if the water heater is not dirty. Clean the heater as described in sections "Maintenance" and "Water heater".
Cold supply air:
Check the air temperature which is set by the thermostat.
Check the tightness of the water heater.
Check if the supply water and control assemblies are in order and operational.
Increased noise and vibration:
Clean the fan as described in section "Fan maintenance".
If the fault can not be removed, please contact the supplier.
ACCESSORIES
SAV
Fan Heater
Fan speed controller MTY
GR
Fan transformer speed controller TGRV
Fan transformer speed controller TGRT
VP
Thermic water valve actuator
6
| EN
B
C
a
[mm]
[mm]
[mm]
[mm]
502
565
44
440
627
565
44
561
777
783
44
711
852
818
44
786
SAV 2000
[50 Hz / V]
~1 / 230
[kW]
0,173
[A]
0,8
[min
]
1392
-1
[°C]
+60
[µF]
8,0
IP-44
#1
MTY1,5 / TGRV1,5
b
b1
c
c1
[mm]
[mm]
[mm]
31
265
53
33
265
53
33
283
53
33
318
57
SAV 4000
~1 / 230
0,484
2,32
1410
+70
8,0
IP-54
#1
MTY2,5 / TGRV4
Room thermostat
T
Room digital thermostat
AM
Mixing point
3-way water valve
VV
2-way water valve
c2
g
e
ød
[mm]
[mm]
[mm]
[mm]
38
170
401
26,5
38
220
455
26,5
38
280
596
26,5
45
280
676
26,5
SAV 6000
SAV 9000
~3 / 400
~3 / 400
0,54
0,992
1,1
1405
+70
-
IP-54
#2
TGRT2
TGRT2
m
[kg]
21,0
34,0
45,0
57,0
1,9
1415
+70
-
IP-54
#2
SAV v2019.06