12. Maintenance
12.1

Cleaning and servicing

!
Before cleaning and servicing, switch off ROLL F4 M
and disconnect mains plug.
!
Do not use any solvent-based cleaning agents. Use
alcohol or similar cleaning agents for plastic parts.
The following work is essential to ensure proper
operation and high performance of the ROLL F4 M:
Servicing
Clean moving mechanical parts, treat with spray oil
or kerosene and lubricate with engine oil or a suitable
grease.
12.2

Spare and wearing parts

The manufacturer cannot accept any liability for
damage arising from the use of non-genuine
replacement parts.
Designation
Standard centering flange
Centering cone 42 - 65 mm
Centering cone 54 - 80 mm
Centering cone 75 - 110 mm
Weight pliers
Manual vernier caliper
Test clip
Calibration weight
Calibration weight (calibrated)
Voltage sticker V 230
Voltage sticker V 110
Direction of wheel rotation sticker
Tab. 2:
Spare and wearing parts
OMCN spa
12.3
i
As part of service and upkeep (every six months), on
flange replacement or in the event of measurement
inaccuracies, it is advisable to calibrate the
ROLL F4 M in the following sequence:
1. Flange calibration.
2. Electronic Vernier caliper and Angular width gauge
calibration.
3. ROLL F4 M calibration.
4. Perform reference measurement.
12.3.1
1. Call up the "Settings and service" menu.
x
2. Enter the password: <r> <r> <o>.
"
The calibration menu is displayed.
Order number
1 695 602 400
1 695 632 500
1 695 652 862
1 695 605 600
1 695 606 500
12.3.2
1 695 629 400
1 695 602 700
i
Follow the instructions shown on the monitor.
1 695 654 377
1 695 654 376
1. Fit the flange (refer to Section 5).
1 695 101 269
1 695 100 854
i
Do not clamp the wheel, do not use any clamping
1 695 653 878
tools.
2. Select flange calibration and confirm with < I >.
« Calibration is started.
3. Close the wheel guard.
« Measurement commences.
"
Flange calibration completed.
"
Unbalance set to "0".
Maintenance | ROLL F4 M | 47
Calibration

Call-up of calibration menu

Calibration with "Go" wheel
Flange calibration
Return to main page.