50 | ROLL F4 M | Decommissioning
12.3.5

Reference measurement

i
Exact centering of the wheel is a basic prerequisite
for this reference measurement and for all
balancing operations.
i
In the following description the audio is activated.
1. Attach a motor vehicle wheel of medium size (e. g.
width 5.5", diameter 14") and in very good condition
to the flange.
2. Enter the wheel data.
3. Close the wheel guard.
« Measurement commences.
4. Create an artificial unbalance by attaching a test
weight of e. g. 60 g to one of the two sides.
5. Close the wheel guard.
« Measurement commences.
« The ROLL F4 M must display precisely this unbal-
ance (value and position) on this side. The value in-
dicated for the other side must not exceed 5 g.
i
To check the position of the unbalance, turn
the wheel until the position recommended for
attachment of the balance weights is attained. The
test weight attached must be vertically beneath the
axis of rotation (6 o'clock position).
!
Calibration must be repeated in the following cases:
$
Deviation from specified unbalance value
(greater than 1 g on test weight side, more than
5 g on other side).
$
Deviation from specified unbalance position (test
weight not between 5:30 and 6:30 position).
6. Remove the test weight.
7. Release the wheel and turn it through approx. 90°.
8. Re-attach the wheel.
9. Close the wheel guard.
« Measurement commences.
"
On completion of this reference measurement, the
display must not exceed a maximum unbalance of 10 g
per side (15 g for particularly heavy wheels). This error
may be caused by the rim centering tolerances. If this
reference measurement indicates greater unbalance,
the components used for centering the wheel must
be checked for wear, play and contamination.
|
1 695 600 693
2016-09-27
13. Decommissioning
13.1
Temporary shutdown
In the event of lengthy periods of non-use:
Unplug the electrical connection.
13.2
Change of location
If the ROLL F4 M is passed on, all the documentation
included in the scope of delivery must be handed over
together with the unit.
The ROLL F4 M is only ever to be transported in the
original or equivalent packaging.
Unplug the electrical connection.
Heed the notes on initial commissioning.
Bolt the ROLL F4 M back onto the pallet.
13.3

Disposal and scrapping

13.3.1

Substances hazardous to water

!
Oils and greases as well as refuse containing oil and
grease (e.g. filters) represent a hazard to water.
1. Substances hazardous to water must not be allowed
to enter the sewage system.
2. Substances hazardous to water must be disposed of
in accordance with the applicable regulations.
13.3.2
ROLL F4 M
and accessories
1. Disconnect the ROLL F4 M from the mains and
detach the power cord.
2. Dismantle the ROLL F4 M and sort out and dispose
of the different materials in accordance with the
applicable regulations.
ROLL F4 M, accessories and packaging
should be sorted for environmental-friendly
recycling.
Do not dispose ROLL F4 M into household
waste.
Only for EC countries:
The ROLL F4 M is subject to the European
directive 2012/19/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of ROLL F4 M prevents
environmental pollution and possible
health hazards.