48 | ROLL F4 M | Maintenance
12.3.3
Calibration of electronic vernier caliper/
gauge arm
i
Follow the instructions shown on the monitor.
1. Select calibration of the slide calliper and of the
angular width gauge and confirm using < I >.
« Calibration begins.
2. Move the slides with distance A and width B to
standby position and press < I >.
A
3. Move the reading cursor of distance 0 mm. Set the
value read and press < I >.
4. Move the cursor of distance A against the interior of
the flange. Measure and set the value read and press
< I >.
5. Keeping the distance A cursor in standby, move the
cursor of width B width against the external part of
the flange and press < I >.
|
1 695 600 693
2016-09-27
6. Assemble the width calibration pin on the external
part of the flange. Move the width cursor against the
end of the pin and press < I >.
B
7. Remove the pin and assemble a 14'' or 15'' steel
sample wheel using the relevant hold-down nut.
8. Set the wheel measurements and, with the distance
reading cursor resting on the wheel itself, press < I
>.
« Procedure completed.