5.
Fitting and removing the
flange
Fitting of the flange is necessary in the following
situations:
+
Commissioning
+
When changing the type of flange
(universal - 3/4/5 hole*)
+
When changing the type of wheel
(passenger car - motorcycle*)
* Special accessories
!
Balancing accuracy will be impaired if the flange has
not been properly fitted to the shaft.Before fitting
the flange, clean and degrease (remove corrosion
protection) the cone of the shaft and the flange
opening.
5.1
Removing flange
i
The ROLL F4 M must be connected to the electric
mains.
1. Press the pedal.
« This blocks the shaft.
2. Slacken off the hexagon socket head bolt.
3. Unfasten the flange by tapping with a rubber-headed
hammer on the cone end.
4. Pull the flange off the cone.
"
Flange detached.
OMCN spa
Fitting and removing the flange | ROLL F4 M | 35
5.2
Fitting flange
i
Clean and degrease the cone of the shaft and the
flange opening.
1. Press the pedal.
« This blocks the shaft.
2. Slide the flange onto the shaft.
3. Tighten the hexagon socket head bolt.
"
Flange fitted.