6.2 - RX4Y RECEIVER
If necessary, users may select the RX4X RECEIVER MENU, used
to manage the parameters relating to the radio unit.
ADD TX
DELETE TX
DELETE ALL
READ MEMORY
MEMORY LOCK/UNLOCK
ADDING A TX USING THE DISPLAY
This procedure allows one or more transmitters to be memorised in the receiver.
(WARNING: if there is not already at least one transmitter in the memory, the first transmitter entered will establish the type of code -
rolling code or fixed code).
1. Access the menu
RX4Y
2. Select the type of channel in which the button is to be saved (CHANNEL 1= step by step; 2= parcial opening; 3= open; 4= lights on/off;
5= memorisation of all 4 codes with preset functions as specified above). Press V to confirm.
3. Press the button of the TX to be memorised.
4. After the button is pressed, the display will show: TRANSMITTER MEMORISED.
5. To add another code, start the procedure again from point 2. To quit the menu, press "X".
The "X" button is effective at any point in the procedure.
If no commands are given for 10 seconds, the receiver automatically quits the memorisation mode.
DELETING A TX USING THE DISPLAY
This procedure allows a radio code to be deleted from the memory of the RX4Y receiver using the transmitter memorised.
1. Access the menu
RX4Y
2. Press the button of the TX to be deleted when prompted.
3. After the button is pressed, the display will show: TRANSMITTER DELETED.
4. When the code has been deleted, the display will show the memory position it was cleared from.
5. To add another code, start the procedure again from point 2.
To quit the menu, press "X". The "X" button is effective at any point in the procedure.
If no commands are given for 10 seconds, the receiver automatically quits the memorisation mode.
CLEARING THE MEMORY OF THE RX4Y RECEIVER
This procedure is used to clear the entire memory of the receiver.
1. Access the menu
RX4Y
2. Confirm the request by pressing "V" or exit using "X".
3. On confirmation, the display will show: MEMORY DELETED.
READING THE RECEIVER MEMORY
This procedure is used to view the radio codes present in the memory of the RX4Y receiver.
1. Access the menu
RX4Y
2. Use ▲ and ▼ to scroll through the codes in the memory. The number of the transmitter in the memory, the radio
code saved and the relative button and channel will appear on the first line of the display, while the second line will
indicate that the code can be deleted, confirming with V.
3. To quit the menu, press "X".
The "X" button is effective at any point in the procedure.
MEMORY LOCK/UNLOCK
This procedure is used to lock or unlock the memory of the RX4Y receiver.
1. Access the menu
RX4Y
0=OFF memory unlocked
1= ON memory locked
N.B. if the receiver is blocked by means of the XR MANAGER device, refer to the user manual of the latter.
28
Allows a new code to be memorised in the receiver
Allows deletion of a code from the receiver
Clears the receiver's entire memory
Displays the codes in the memory
Unlocks or locks the receiver's memory
ADD TX
DELETE TX
CLEAR ALL
READ MEMORY
MEMORY
LOCK/UNLOCK
Proceed as follows:
14A
RX4Y
A
B
D
C
M = PRESET
FUNCTIONS