Key Automation 14A Anleitungen Und Hinweise Zu Installation Und Einsatz Seite 27

Modulares steuergerät für einen oder zwei 24-vdc-motoren
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 58
14
DEAD MAN
GATE OPEN
15
INDICATOR
16
MAINTENANCE
17
MAINTENANCE FLASH
ELECTROLOCK
18
ACTIVATION
WATER HAMMERING
19
IN OPENING
WATER HAMMERING
20
IN CLOSING
MOTOR RELEASE AT
21
STOP
22
START UP BOOST
23
CLOSING DELAY M 1
24
ENCODER
25
ENCODER PULSES
CIRCUIT BOARD INPUT
26
LOCKING
27
DEFAULT
* The OPEN command from the transmitter and the 14A control unit will activate the parcial gate electric lock when the parameter is set on
3 or 4. The activation time is as set in parameter 18
** If the setting is 4, the GATE OPEN WARNING LIGHT output must be connected to the coil of a relay (24 Vdc coil). Interface the relay
contact with the electric lock
*** For RÉVO motors, DEFAULT = 2
**** Gate closed = output activated; Gate not closed = output deactivated
0 = off
1 = on (safety devices disabled)
0 = deactivated
1 = gate open light ON/OFF
2 = gate open light proportional
3 = electric lock for partial gate *
4 = electric lock for partial gate with relay interface **
5 = Traffic light
When open COM/IND activated and COM/ELEC deactivated
(GREEN)
Not open COM/IND deactivated and COM/ELEC activated (RED)
Service interval cycle threshold
Enabling of continuous flashing when service is required (only
active with gate closed).
0 = off
1 = on
0 = magnetic electrolock. Output works only when the gate is
closed. We recommend to set the pre-flash to 2 seconds ****
Activated for from 1 to 20 seconds when the motors start to open
the gate
From motor M1 closed
0 = off
Motor M1 activated for from 1 to 30 seconds in the closing
direction to ensure that the electric lock releases
From motor M1 closed
0 = off
Motor M1 activated for from 1 to 30 seconds in the closing
direction to ensure that the electric lock engages
Motor release from limit switch. Useful for lightweight gates
0 = off
1 to 10 release levels (1 = minimum release, 10 = maximum
release)
High-speed motor start-up. Useful for heavy gates in winter
0 = off
1 = on
2 = maximum
Leaf 1 closing delay with gate open
0 = Off
1 = 1 to 180 Seconds On
1 = Off (use of virtual encoder)
2 = On (use of motor's physical encoder)
1 to 10 pulses per revolution of the physical encoder (only with 24
set as "2")
0 = Circuit board inputs active
1 = SBS-CLOSE-OPEN-PAR circuit board inputs deactivated
WARNING! If the parameter is set as 1, the control unit will request
a 4-figure numerical password, which will have to be entered again
to return the parameter to 0
Restoring the default values
0
0
1
0
0
5
x 1000
10
1
200
cycles
0
0
1
2
0
20
0
0
30
0
0
30
0 ***
0
10
0
0
2
1
0
180
1
1
2
1
1
10
0
0
1
0
0
1
EN
s
s
s
s
27

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis