Herunterladen Inhalt Inhalt Diese Seite drucken

About This Documentation; Notes On Safety - Aventics ECD-IV Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
AVENTICS | ECD-IV | R412025990–BAL–001–AC | English
1

About this Documentation

These instructions contain important information for the safe and appropriate
assembly and commissioning of the product.
O Read these instructions carefully, especially chapter 2 "Notes on safety",
before you start working with the product.
Documentation validity
O This documentation is valid for ECD-IV series compact ejectors.
Additional documentation
O Also follow the instructions for the other system components.
O Please also observe the generally relevant, statutory and other binding
regulations of European and national legislation and the national regulations for
accident prevention and environmental protection in your country.
For further information about IO-Link mode (R412026283) and an electronic device
description (IO Device Description, IODD), please visit our Media Center at
www.aventics.com/media-centre/
Use the search bar to search for: IO-Link (ECD-IV) or IODD
Presentation of information
Warnings
In this document, there are safety instructions before the steps whenever there
is a danger of personal injury or damage to the equipment. The measures described
to avoid these hazards must be followed.
Structure of warnings
Hazard type and source
Consequences of non-observance
O Measures to avoid these hazards
Meaning of the signal words
Indicates a hazardous situation which, if not avoided, will certainly result in death
or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or
serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or
moderate injuries.
Indicates that damage may be inflicted on the product or the environment.
Symbols
Operation may be impaired if this information is disregarded.
2

Notes on safety

The product has been manufactured according to the accepted rules of current
technology. Even so, there is a risk of injury or damage if the following general safety
instructions and the specific warnings given in this instruction manual are not
observed.
O Please read all these instructions carefully before working with the product.
O Keep these instructions in a location where they are accessible to all users at all
times.
O Always include the operating instructions when you pass the product on to third
parties.
Intended use
The ejector is exclusively intended for installation in a machine or system or for
combination with other components to form a machine or system.
O Use is permitted only under the operating conditions and within the performance
limits listed in the technical data. Only use neutral gases in accordance with
EN 983 as media.
O Exclusively use the ejector for vacuum generation in pneumatic systems.
Compact ejectors are intended for professional use only and not for private use.
Compact ejectors may only be used for industrial applications (class A in accordance
with DIN EN 55011). An individual license must be obtained from the authorities or
an inspection center for systems that are to be used in a residential area (residential,
business, and commercial areas).
Intended use includes having read and understood these instructions, especially
chapter 2 "Notes on safety".
SIGNAL WORD
DANGER
WARNING
CAUTION
NOTICE
Improper use
O Do not use the ejector in explosive areas.
O Do not use the ejector to suction fluids, aggressive or flammable gases, and bulk
materials (e.g. granulate).
Personnel qualifications
Assembly, disassembly, commissioning, and maintenance (incl. service and care)
require basic mechanical and pneumatic knowledge, as well as knowledge of the
appropriate technical terms.
In order to ensure operational safety, these tasks may only be carried out by
qualified personnel or an instructed person under the direction of qualified
personnel.
Qualified personnel are those who can recognize possible hazards and institute the
appropriate safety measures, due to their professional training, knowledge,
and experience, as well as their understanding of the relevant regulations pertaining
to the work to be done. Qualified personnel must observe the rules relevant to the
subject area.
General safety instructions
W
Observe the valid local regulations in the country of use to protect the
environment and avoid workplace accidents.
W
Only use AVENTICS products that are in perfect working order.
W
Examine the product for obvious defects, such as cracks in the housing or
missing screws, caps, or seals.
W
Do not modify or convert the product.
W
Opening the product will destroy the "tested" label. This voids the warranty.
W
The warranty will not apply if the product is incorrectly assembled.
W
Do not place any improper mechanical loads on the product under any
circumstances.
W
Generally protect the product from damage.
W
Product warnings and information must be legible, i.e. not covered by paint, etc.
W
No liability is assumed for damage caused by the use of non-original spare parts
or accessories. All wear parts are excluded from warranty.
Safety instructions related to the product and technology
Open vacuum/exhaust air connections and vacuum cup
Risk of injury by suctioning of eyes or other parts of the body.
Risk of injury due to exhaust air and any other parts and debris that may have
been drawn in being emitted from the exhaust air connection at high speed.
O Never look into vacuum openings, neither suctioning or not suctioning
(e.g. vacuum connections or connected vacuum cups).
O Never look into or enter the exhaust air stream.
On installation
W
Make sure the relevant system component is not under pressure or voltage
before assembling the product or when connecting and disconnecting plugs.
Protect the system against being restarted.
W
Lay cables and lines so that they cannot be damaged and no one can trip over
them.
W
Observe the connection symbols and connection designations on the ejector.
W
Only use the designated connection options, mounting holes, and mounting
material.
W
Before commissioning, make sure that all the connection seals and locks are
properly installed and undamaged to prevent fluids and foreign bodies from
penetrating the product.
W
Only use the following power supply for the components:
– 24 V DC PELV circuits in accordance with DIN EN 60204-1/IEC 60204-1.
– The PELV power source must be a safety isolation transformer in accordance
with IEC 61558-1 or IEC 61558-2-6, or a power source offering the same
degree of safety as a safety isolation transformer.
– Make sure that the power supply of the power pack is always less than
300 V AC (outer conductor – neutral wire).
W
In case of heavily contaminated vacuum/ambient air, use a VFC cup version
vacuum filter between the vacuum connection and the volumes to be evacuated.
During commissioning
W
Check that all the electrical and pneumatic connections are allocated or closed.
Only commission fully installed products.
W
When the supply voltage is switched on, output signals may change (discrete
signals as well as IO-Link signals). Depending on the machine's/system's
functionality, this may lead to severe personal injury or damage to equipment.
WARNING