MODEL
INPUT PARAMETERS
Nominal DC Power [kW]
Max. Recommended DC Power [kW]
Operating Input Voltage Range [V]
Full Power MPPT input voltage range (symmetrical load) [V]
Full Power MPPT input voltage range (asymmetrical load) [V]
Absolute Max. Input Voltage [V]
Activation voltage "Vstart" [V]
No of independent MPPT trackers
Max. Input Power, each MPPT [kW]
No. of DC Inputs
Max. DC Current, each MPPT [A]
DC Connection
INPUT PROTECTION
Reverse polarity protection
Fuse rating, each input (-FS suffi x versions only)
DC side varistors
PV array Insulation Control
DC Switch (-S/-FS suffi x versions only)
OUTPUT PARAMETERS
Nominal AC Power [up to 50°C, kW]
Max. AC Power [kW]
AC Grid Connection
Nominal AC Voltage [V]
Maximum AC Voltage Range [V]
Nominal AC Frequency [Hz]
Max. AC Line Current [A]
AC Connection
Line Power Factor
AC Current Distortion [THD%]
OUTPUT PROTECTION
AC side varistors
Ground fault protection (AC + DC leakage current)
ENVIRONMENTAL PARAMETERS
Cooling
Ambient Temp. Range [°C]
Opertaing Altitude [m]
Acoustical Noise [dBA]
Environmental IP Rating
Relative Humidity
MECHANICAL
BOX Dimensions [H x W x D]
Overall Dimensions (whit fl anges) [H x W x D]
Weight [kg]
(*) Only for –DE version Nominal AC Power= 4600W
Photovoltaic Inverters
PVI-5000-OUTD
4,8
5,75
150-530
220-530 (@ 4kW) / 90-530 (@ 0,8kW)
200 nominal (adjustable within the range 120Vdc-350Vdc, independently/each input)
8 x MultiContact Ø 4mm (4 male - positive input + 4 female - negative input)
Conductor cross section: 4-6mmq/AWG12-10 - Cable Ø w/insulator: 3-6mm
NA
4 ( 2 for each MPPT ), thermally protected
4,6
5 (*)
25
Conductor Cross Section: Solid: 0,5-16mmq / Stranded: 0,5-10mmq / AWG20-6
Cable Gland: M32 - Cable Ø: 13-21mm
<3,5% at rated power with sine wave voltage
-25 / +60 (output power derating above 50°C)
PVI-6000-OUTD
0,7xVstart - 580 (360 nominal)
220-530 (@ 4kW) / 120-530 (@ 2,2kW)
600
2
4
4 (2 each MPPT)
18 (22 shortcircuit)
Mating cable connector included
Yes
according to VDE0126-1-1
Integrated (Rating: 600Vdc / 25Adc)
single phase 230Vac 50Hz + PE
230
180-264
50
Cage-clamp terminal block
1
2, plus gas arrester to ground
according to VDE0126-1-1
Natural cooling
2000
<50 @1mt
IP65
0-100% condensing
740 x 325 x 208
910 x 325 x 222
26
6,2
6,9
180-530
NA
6
6
30