5.2
Storing the Displayed Value
Storing the displayed value is possible only if no Reset func-
tion was setup, see section 4.4.3
As long as a high-signal (> 4 V, < 10 V) is present at the
Latch input, the current value in the display is "frozen". Meas-
urement and totalizing continue to run in the background.
5.3
Resetting the Totalizer
Resetting is only possible if the Latch / Reset input has been
setup for the function reset, see section 4.4.3
Depending on the setting, the resetting is carried out either
manually with the red key
(>4 V, <10 V) at the reset input. The total value will be de-
leted.