Herunterladen Inhalt Inhalt Diese Seite drucken

Storing The Displayed Value; Resetting The Totalizer - Kübler CODIX 552 Bedienungsanleitung

Prozessanzeige für strom-/spannungssignale mit totalisator
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5.2

Storing the Displayed Value

Storing the displayed value is possible only if no Reset func-
tion was setup, see section 4.4.3
As long as a high-signal (> 4 V, < 10 V) is present at the
Latch input, the current value in the display is "frozen". Meas-
urement and totalizing continue to run in the background.
5.3

Resetting the Totalizer

Resetting is only possible if the Latch / Reset input has been
setup for the function reset, see section 4.4.3
Depending on the setting, the resetting is carried out either
manually with the red key
(>4 V, <10 V) at the reset input. The total value will be de-
leted.
Fritz Kübler GmbH
Zähl- und Sensortechnik
P.O.B. 3440
D-78023 VS-Schwenningen
24
21.
and /or electrically with a pulse
Tel. +49 (0) 77 20 / 39 03-0
Fax +49 (0) 77 20 / 2 15 64
info@kuebler-gmbh.de
www.kuebler-gmbh.de
21.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Codix 555

Inhaltsverzeichnis