Starting to use the power source

General remarks

Before starting to use for the first time, read the section headed "Safety rules".
Utilisation for
The welding machine is intended to be used solely for rod electrode and TIG welding.
intended purpose
Any other use, or any use going beyond the above, is deemed to be "not for the intended
only
purpose" and the manufacturer shall not be liable for any damage resulting therefrom.
Utilisation for the intended purpose" shall also be deemed to encompass:
-
-
Never use the welding machine for thawing frozen pipes!
Machine set-up
The welding machine is tested to "Degree of protection IP23", meaning:
regulations
-
-
The welding machine can be set up and operated outdoors in accordance with IP23.
However, the built-in electrical components must be protected against direct wetting.
The venting duct is a very important safety feature. When choosing the machine locati-
on, make sure that it is possible for the cooling air to enter and exit unhindered through
the louvers on the front and back of the machine. Any electroconductive metallic dust
from e.g. grinding-workmust not be allowed to get sucked into the machine.

Mains connection

Fig.6
The machine can be run as standard on a mains voltage of 400 V~ (+/- 20%). Thanks to
its +/-20% tolerance range, it can also be run on the 415 V~ mains.
the observance of all instructions in the operating manual
the carrying out of all prescribed inspection and maintenance work
Protection against penetration by solid foreign bodies with diameters larger than 12
mm
Protection against spraywater up to an angle of 60° to the upright
Warning! A welding machine that topples over can easily kill someone! Place
the welding machine on an even, firm floor in such a way that it stands firmly.
320 V~
400 V~
-20%
Tolerance ranges of the mains voltage
Note! If the machine is designed to run on a special voltage, the Technical Data
shown on the rating plate apply. The mains plug and mains supply lead, and
their fuse protection, must be dimensioned accordingly.
The welding machine is designed to run
480 V~
on the mains voltage given on the rating
plate. The mains cable and plug are
+20%
ready-mounted. For details of fuse protec-
tion of the mains supply lead, please see
the Technical Data.