Description of controls

Description of
controls
(A)
(C)
(B)
Fig.4
(1) Mains switch
(2) Operational readiness indicator
(3) Welding current dial ... for continuous adjustment of the welding current
Important! If the TP 2000 R.C. welding machine is used with a remote-control unit, then
it is only possible to adjust the welding current on this r.c. unit. The maximum welding
current that can be selected is indicated by the welding dial on the machine (3) .

(4) Malfunction indicator

(5) Arc-force dial ... for influencing the amperage of the short-circuit current at the
(6) TIG welding indicator ... lights up when the arc-force dial (5) is set to "TIG welding"
(A) (+) - Current socket with bayonet latch ... for connecting:
(B) (-) - Current socket with bayonet latch ... for connecting:
(C) Remote-control connection socket (only on TP 2000 R.C.) ... for connecting up a
Controls on the welding machine
-
flashes when the machine is in the "Setup menu"
-
lights up when the mains switch is shifted to "1"
-
flashes when the mains voltage is outside the tolerance range
-
lights up when the unit is thermally overloaded (i.e. overheats)
instant of droplet transfer (setting range: 0-100 A)
(turned completely anticlockwise)
-
Manual electrode or earthing cable for manual electrode welding (depending on
type of electrode)
-
Earthing cable for TIG welding
-
Manual electrode or earthing cable for manual electrode welding (depending on
type of electrode)
-
Welding torch for TIG welding (current connection)
TR 2000 / TR 4000 remote-control unit
(1)
(5)
Fig.5
Controls and indicators on the operating
panel
3
(3) (2)
(6)
(4)