7.4 Timing Chart
The following chart shows the data input and printing timings.
Supply
T1, T2, T3
T4
T5
T6
7.5 Data Receiving Control
When the BUSY signal is at "LOW," the data can be received from the host, but when at "HIGH," it cannot be
received.
7.6 Buffering
The main body has a 3KB input buffer.
data can be buffered.
0.5µs MIN
270ns MAX
2.3µs TYP
500ms MIN (At power-on)
The host side is immediately released because a large amount of
33
CBM-292/293 User's Manual