How to Connect the Open-Collector Inputs of the
Controller
Here below there are the typical connections of the open collector
input of SQ 337 to an external sys-tem. Two cases are considered:
1. the customer supplies the 24 Vdc
2. the customer does not supply the 24 Vdc
Please note that on the connector a 24 Vdc, 60 mA voltage, a
GROUND signal and the open collector pin are available.
Figure 15
TV 801 Navigator User Manual / 87-900-953-01

How to Connect the Open-Collector Inputs of the Controller

Case 1
(G)
Technical Information
223/252