17
Technical Information
Interconnections
When no external input-output device is available this connector
must be closed with the supplied mating connector that short-circuits
the START and INTERLOCK inputs with the GROUND input (see the
following figure).
Figure 9
How to Connect the Open Collector Input of the
Controller
Here below there are the typical connections of the open collector
input of TV 301-P Navigator Controller to an external system. Two
cases are considered:
1.
2.
Please note that on the connector a 24 Vdc, 60 mA voltage, a
GROUND signal and the open collector pin are available.
184/224
the customer supplies the 24 Vdc
the customer does not supply the 24 Vdc.
TV 301-P Navigator Controller User Manual / 87-901-001-01 (B)