with adequate safety accessories to prevent accidents.
Work far from open flames, do not short-circuit the bat-
tery poles, do not generate sparks and do not smoke.
The batteries are normally supplied full of acid solution
(for the Pb-Acid type) and ready for use. In any case, fol-
low the steps indicated in the manual supplied with the
battery and carefully follow the instructions regarding
safety and operating procedures.
6.2
BATTERY INSTALLATION AND PREPARA-
TION
• These operations must be carried out by specialised
personnel.
Make sure the two tanks are empty. If not, empty them in
accordance with the specific procedure.
Lift the recovery tank by 90°, making sure it is stable in
that position. This provides access to the battery com-
partment from the top.
Disconnect the Anderson connector of the battery wiring
from the Anderson connector of the machine wiring. Al-
ways hold the connectors with the hands and never pull
on the cables.
• Attach the battery wiring to the battery, connect-
ing the terminals only on the poles marked with the
same symbol (red wiring "+", black wiring "-")! A bat-
tery short-circuit may cause an explosion!
Run the cables toward the wiring outlet opening (on one
side of the box, only for Pb-Acid batteries), tighten the
terminals at the poles and cover them with Vaseline. In-
sert the battery putting the opening in the box (only for
the Pb-Acid battery) in a position to run the electric wir-
ing to the connector of the machine wiring. After check-
ing that all the controls on the panel are in position "0"
or at rest, connect the battery connector to the machine
connector.
• Close the battery compartment (lowering the recovery
tank) making sure not to crush any wires.
6.2.1

SETTINGS THROUGH THE

CONTROL PANEL

Make sure that the Key is turned to OFF position (O), then
Make sure that the Key is turned to OFF position (O), then
press simultaneously the buttons
press simultaneously the buttons
ture N-1) and
(-) "SPEED" (Picture N-6) on the control
panel (Picture N).
At the same time, turn the key to ON position (I)
When, on the display, it appears the word "PASSWORD"
(picture N-7), release the buttons previously pressed.
(picture N-7), release the buttons previously pressed.
Now, by using the buttons
it is possible to scroll through the settable parameters
which you can choose from dashboard:
- TIPO LOGO
(LOGO TYPE)
- TIPO BATTERIA
(BATTERY TYPE)
- LINGUA
(LANGUAGE)
To select and change the desired parameter, press the
To select and change the desired parameter, press the
button
(-) "SPEED REDUCTION" (Picture N-6) or press
the button
"FORWARD / REVERSE GEAR".
To exit from the calibration select the button
"BRUSHES" (Pic-
"BRUSHES" (Picture N-1),
"SUC-
TION" (Picture N-2)
MEANING OF SETTABLE PARAMETERS:
LOGO TYPE
Range: CTM, FASA, LAVOR
BATTERY TYPE
Range: Pb Acid / Gel
LANGUAGE
Language that is displayed. In this version are available:
ITALIAN and ENGLISH
6.3

MACHINE PREPARATION

• Before starting to work, wear non-slip shoes, gloves
and any other personal protection device indicated by
the supplier of the detergent used or considered nec-
essary based on the operating environment. ☞ Do the
following before starting to work. Refer to the relative
sections for a detailed description of these steps:
Check the battery charge level and charge, if necessary.
Mount the brushes or scraper disks (with the abrasive
disks) that are suitable for the surface and work involved.
Mount the squeegee, check that it is solidly attached and
connected to the suction hose and that the drying straps
are not too worn.
Make sure that the recovery tank is empty. If not, empty
it completely. Check and completely close the detergent
solution release control.
Fill the detergent solution tank with a mix of clean water
and non-foaming detergent in an adequate concentra-
tion through the rear hole. Leave 7 cm between the
mouth of the plug and the level of the liquid.
☞ To avoid risks, become familiar with the machine
movements, carrying out test runs on a large surface
without obstacles.
To obtain the best results in terms of cleaning and equip-
ment service life, you should do the following simple but
important operations:
- Identify the work area, moving all possible obstacles out
of the way; if the surface is very extensive, work in con-
tiguous and parallel rectangular areas.
- Choose a straight work trajectory and begin working
from the farthest area to avoid passing over areas that
have already been cleaned.

7. OPERATING INFORMATION

7.1

BATTERY CHARGING

Prepare and check the battery charge according to the
instructions provided in the specific section.
Detach the battery connector (the one with the handle)
from the machine power connector and connect it to the
battery charger connector.
• Do not connect the battery charger to the scrubber-
drier's main wiring connector.
Hold the connectors with the hands; do not pull them
using the cables.
If the machine is equipped with Pb-Acid batteries, charge
only in a well-ventilated area, lift the top tank and open
32