11. Warranty

The appliance is covered by a warranty as this has been agreed upon sale.
FOR AUTHORISED SERVICE PERSONNEL ONLY
It is mandatory that the Customer performs the following operations during the Maintenance of an ICM
once or twice a year, using a vacuum cleaner:
Cleaning of the condenser
Cleaning of the dust filters (if applicable).
If the ICM is placed in an environment where dust is accumulated on the condenser, then the
condenser has to be cleaned more often.
Additionally it is recommended that the following operations are carried out during preventive
maintenance:
1. Mechanical System:
Check that the equipment is correctly positioned and leveled.
Check that the front and back grid are fixed in place.
Check that the fan support and fan grid are fixed in place.
Check the draining system and unclog if necessary.
20
HANDLING & TRANSPORTATION GUIDELINES
The merchandiser should always be transported:
in upright position (unless otherwise authorized by the supplier)
on appropriate vehicles (e.g. with air shock absorbers and tail lift)
and from appropriate roads
strapped on a pallet ensuring proper protection of the cooling
mechanism
packed and stored properly, ensuring proper protection of the
cooling mechanism
PREVENTIVE MAINTENANCE GUIDELINES
PRIOR TO ANY CLEANING OR MAINTENANCE PROCEDURE (INSIDE OR
OUTSIDE THE DEVICE), UNPLUG THE ICM! REMOVE THE PLUG AND
MAKE SURE THAT THE OPERATOR CAN CHECK FROM ANY OF THE
POINTS WHICH HE HAS ACCESS THAT THE CABLE IS UNPLUGGED.