8. TROUBLESHOOTING

PROBLEM
1. When the key is turned to «RUN», the
indicator light or the control panel remain
switched off
2. With the key on «START» the light flashes
and the starter motor does not run
3. With the key is turned to «START» the light
or the control panel come on, but the starter
motor is not activated
4. With the key on «START», the starter motor
runs but the engine does not start
EN
32
LIKELY CAUSE
The safety device of the electronic
circuit board has cut in due to:
– badly connected battery
– battery terminals crossed
– completely flat battery
– fuse blown
– electronic circuit board wet
– conditions are not met to allow starting
– insufficiently charged battery
– malfunction on the starter relay
– insufficiently charged battery
– faulty fuel supply
– faulty ignition
SOLUTION
Turn the key to «STOP» and look
for the cause of the problem:
– check connections (
3.4)
– check connections (
3.4)
– recharge the battery (
6.2.3)
– replace the fuse (10 A) (
6.3.5)
– dry using tepid air
– check that the conditions allowing starting
are met (
5.2.a)
– recharge the battery (
6.2.3)
– contact Your Dealer
– recharge the battery (
6.2.3)
– check the level in the tank (
– open the fuel stopcock (if present) (
– check the fuel filter
– check that spark plug cap is securely fitted
– check that the electrodes are clean
and have the correct gap
5.3.3)
5.4.1)