To replace the backflow stop

Replace a defective backflow stop.
1. Unscrew the adapter with the hose
connection (9) on the angle adapt-
er (11) and remove the backflow
stop (10a) and seal (10b).
2. Insert the seal (10b) into the
back flow stop (10a).
3. Set the backflow stop (10) be-
tween the angle adapter (11)
and the adapter with the hose
connection (9) in such a man-
ner that the stop is opened in
the flowing direction and closed
against the flowing direction.

To clean the paddle wheel

In the case of too severe precipitation in
the pump casing (3), the lower part of the
pumps must be disassembled as follows:
1. Loosen the 3 screws on the un-
derside of the base (4) and take
off the base.
2. Clean the paddle wheel with
clear water.
Caution! Do not place or support
the pump on the paddle wheel!
3. Insert the sealing ring (13) into
the base (4).
4. Position the base (4) on the
pump casing (3) such that the
notch (14) on the base (4) is at
the level of the pump output (5).
Any measures above and beyond these, par-
ticularly opening the equipment, are to be
carried out by an electrician. In the case of
repairs, always contact our service centre.

Storage

Clean the pump before storage.
Store the appliance in a dry, frost-free
place, and where children cannot gain
access to it.
When the pump is not to be used for
a longer period, it must be thoroughly
cleaned after its last use, and before it
is next used. Otherwise there may be
problems in starting the pump, caused
by deposits and residues.
Waste Disposal
and Environmental
Protection
Be environmentally friendly. Return the tool,
accessories and packaging to a recycling
centre when you have finished with them.
Electric appliances should not be dis-
posed of in the domestic garbage.
Hand the tool in at a recycling centre. The
plastics and metal parts can be separated
and recycled. Ask your Service Center
about this. Defective units returned to us
will be disposed of for free.

Spare Parts Order

When buying parts for the submersible
water pump, use the service address or fax
number given.
Please enter your machine type and the
item number of the part you are ordering
or its position on the exploded drawing.
Backflow stop .......... item No. 91101243
The backflow stop is subject to wear; its
replacement is not covered by guarantee.
GB