1
PRECAUTIONS
The CRISTEC equipment includes the following :
1 box containing the battery charger's electronic function.
A AC input connector
A DC output connector
this user manual
1 specific packing
This document applies to battery chargers from the YPOWER range as listed on the cover (available in colours on our
website www.cristec.fr).
The manual is intended for users, installers and equipment maintenance staff. Please read this manual carefully before
working on the charger.
This manual should be kept safely and consulted before attempting any repairs because it contains all the information
required to use the appliance.
This document is the property of CRISTEC; all the information it contains applies to the accompanying product. CRISTEC
reserves the right to modify the specifications without notice.
1.1
P
(
RECAUTIONS
Material of class I according to NF EN 60335‐2‐29 standards.
The instructions of installation are contained in the NFC 15‐100 standards and in the specific standard "for pleasure
boats – electrical systems – installation of distribution of alternating current" ISO13297 reference.
The installation must be carried out by an electrician or a professional installer.
The AC network must be disconnected before starting any maintenance work on the equipment.
This equipment is not intended to be used by children.
Main precaution
Before handle the charger, please imperatively read carefully this manual.
Precautions regarding the electric shocks
Risk of electric shock and danger of death: it's strictly forbidden to interfere in the charger when under
voltage.
Precautions regarding accidental earth leaks
The charger's PE terminal must be earthed and connected before any other terminal.
The charger must be closed before it is turned on with the screw provided for the purpose.
Accidental leakage current between phase and earth : standard NFC15‐100 should be followed when
installing.
Use the services of an electrician or professional installer to make the necessary connections. The
charger should be connected to a system having a 30mA differential two‐poles circuit‐breaker.
Accidental leakage current between the charge circuit and the earth : accidental current leakage at the
earth must be detected by means of an independent protective device outside the charger (a residual
current device or an insulation detector).
–
WARRANTY
)
–
WARNING
PROVISIONS RELATING TO SAFETY
20