Herunterladen Inhalt Inhalt Diese Seite drucken

Device Elements; Start Up; Operation - Kärcher NT 40/1 Tact Bs Originalbetriebsanleitung

Bäckersauger
Vorschau ausblenden Andere Handbücher für NT 40/1 Tact Bs:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Device elements

1 Electrodes
2 Holder for suction pipe
3 Push handle
4 Hose hook
5 Air outlet, working air
6 Suction head
7 Suction head lock
8 Recessed grip
9 Dirt receptacle
10 Steering roller
11 Handle
12 Air inlet, motor cooling air
13 Suction support
14 Stop for tool box
15 Fixing eyelet
16 Filter cover
17 Carrying handle
18 Rotating knob
19 Holder for floor nozzle or oven nozzle
20 Fastening screw for slider
21 Power cord
22 Filter frame
23 Flat fold filter (PES)
24 Filter dedusting
25 Nameplate

Start up

ATTENTION
The flat pleated filter must always be in
place while vacuuming.
Anti-static system
Static charge is deflected by providing
earthing to the connection nozzles. This
prevents the formation of sparks and cur-
rent shocks due to attachments (option)
with electrical conductivity.
Wet vacuum cleaning
– If wet dirt is vacuumed with the uphol-
stery or crevice nozzle, or if water is
sucked up from a container, it is recom-
mended to deactivate the "automatic fil-
ter cleaning" function.
– If the maximum liquid level is reached
the appliance will turn off automatically.
– In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
– After the wet vacuuming: Clean the flat
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.
Clip connection
Illustration
The suction hose (special accessories) is
equipped with a clip system. All accessory
parts with a nominal width of 35 mm can be
connected.
ATTENTION
At the latest after 50 oven cleanings, the flat
folded filter must be replaced.
ATTENTION
In order to guarantee safe operation of the
vacuum cleaner, hot air (max. temperature
200 °C) should under no circumstances be
suctioned for longer than 5 minutes without
interruption.
Appliance OFF
Appliance ON
Automatic filter cleaning: OFF
Appliance ON
Automatic filter cleaning: maxi-
mum interval
Appliance ON
Automatic filter cleaning: mini-
mum interval
Turning on the Appliance
 Plug in the mains plug.
 Set the rotary switch to the desired pro-
gram.
– 2
EN

Operation

Rotating knob
13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis