2.1 Installing the track
Screw-fit mounting brackets/ceiling
mounts to the track. When wall-mount-
ing, any unevenness of the wall of up to
any unevenness of the wall of up to
any unevenness of the wall of up to
±3 mm can be compensated by moving
the bracket within the slot.
No mounting brackets/ceiling mounts are
required for direct mounting.
Mount the rail at every second hole.
If the clip-on trim panel is used, fit clips
and spacers as described in section "Fit-
ting the clip-on trim panel".
Install the track to wall or ceiling, making
sure that the track is mounted horizontally.
Observe distances in attachment B.
For wall mounting, fit running rail and fix-
ing bracket with spacers of at least 8 mm
thickness.
2.2 Preassembling the door leaf
Using screws, fit support plates to the
upper end face of the door at intervals of
60 mm from the edge and centred on the
leaf thickness.
Two support plates per door leaf. The
open end of the slot must face the wall.
Fit coupling bracket half-way between the
support plates.
Make sure the slotted edge faces the
outside and is positioned about 13 mm
outside the leaf axis.
Wall mounting
1
2
The
The
3
Ceiling mounting
13
13
GB